Introduction
Background of Standard Formulation and Technological Evolution
This standard was compiled based on the project approval document No. 377 of the Ministry of Housing and Urban-Rural Development in 2011, led by the China Academy of Urban Planning and Design, and completed jointly by 12 water supply units and scientific research institutions across the country. The technological evolution presents three characteristics:
| Development stage | Technical characteristics | Monitoring indicators |
|---|---|---|
| Initial stage (before 2000) | Manual sampling + laboratory testing | Conventional 9 items |
| Development stage (2000-2015) | Single-point online monitoring | Basic indicators such as turbidity/residual chlorine |
| Mature stage (2015 to present) | Full-process intelligent monitoring system | Biological toxicity + characteristic pollutants |
Core monitoring indicators and technical requirements
1. Gradual monitoring of key water quality indicators
2. Key parameters of instrument performance
| Instrument type | Repeatability | Response time | MTBF |
|---|---|---|---|
| Online chlorine monitor | ≤3% | ≤2.5min | ≥720h |
| Ammonia nitrogen analyzer | ≤5% | ≤5min | ≥720h | ≤5% | 5-10min | ≥2000h |
Innovative Technology Applications
1. Comprehensive Biological Toxicity Monitoring
The standard incorporates two biological early warning technologies for the first time:
- Luminescent bacteria method: verified by zinc ion EC50 (error ≤5%), CF value must be controlled between 0.6-1.8
- Fish behavior method: zebrafish behavior analysis sensitivity reaches 0.05TU, requiring 25fps high-speed camera
2. Intelligent operation and maintenance system
Establish a three-level data validity review mechanism:
- Equipment self-check: automatically mark over-range/fault data
- Manual review: daily check for abnormal fluctuations
- Quality control comparison: weekly standard sample calibration (e.g. chlorine meter requires 0.05-1.0mg/L two-point calibration)
Implementation suggestions
- Cleaning the turbidity meter with hydrochloric acid once a week
- Calibration of the UV absorber with potassium hydrogen phthalate standard solution every month
- Replace the test fish of the biological toxicity meter every 15 days
| Maintenance items | Frequency within the water plant | Frequency at the pipe network |
|---|---|---|
| Sensor cleaning | Weekly | Every two weeks |
| Comparison of actual water samples | Daily | Weekly |
| Lightning protection inspection | Monthly | Quarterly |