CY/T 229-2020 in English
VALIDDetermination of volatile organic compounds in printed products for reading - Method of environmental chamber
- Issued on:2020-11-16
- Implemented on:2021-02-01
- File Format:PDF
- Delivery:Via email within 5 business days
$340.00
本标准规定了阅读类印刷品中释放的挥发性有机化合物测试方法。
本标准适用于阅读类印刷品中甲醛、苯系物、总挥发性有机化合物释放量的测定。其他类印刷品挥发性有机化合物检测可参照使用。
Introduction
Analysis of the core content of the standard
This standard establishes a systematic detection method for the release of formaldehyde, benzene and total volatile organic compounds (TVOC) in reading-related printed materials. A climate chamber is used to simulate the real environment for sample pretreatment, and different pollutants are determined by thermal desorption-GCMS and spectrophotometry.
Comparison of key technical parameters
| Test items | Sampling volume | Lower limit of detection | Precision requirements | Characteristic parameters |
|---|---|---|---|---|
| Benzene series | 3-10L | 0.002mg/m³ | Repeatability≤0.01mg/m³ | Tenax TA adsorption tube |
| TVOC | 6L(recommended) | 0.05mg/m³ | Repeatability≤0.03mg/m³ | n-hexane-n-hexadecane range |
| Formaldehyde | ≥10L | 0.01mg/m³ | Relative deviation≤20% | Phenol reagent spectrophotometry |
Key points of sample preparation
1. Pretreatment conditions: The sample needs to be treated at (33±2)℃, (50±5)%RH for (6±0.5)h, and the booklet should be unfolded into 7 parts using a bracket to ensure air contact
2. Background value control: Formaldehyde ≤ 0.006mg/m³, single VOC ≤ 0.005mg/m³, TVOC ≤ 0.05mg/m³
3. Special treatment: samples with too large an area need to be cut, but books with full size can be placed in the climate chamber and kept as they are
Innovation of detection method
1. Dual standard system: gas standard method (4.2.1.1.2.1) and liquid standard method (4.2.1.1.2.2) are used to establish calibration curve
2. Secondary thermal desorption technology: set the main desorption temperature of 260-280℃ and cooperate with -30℃ cold trap focusing to improve detection sensitivity
3. Cross-validation: insert every 20 samples into the standard tube for verification, and recalibration is required if the deviation exceeds 15%
Implementation suggestions
1. Equipment selection: the climate chamber should comply with the requirements of CY/T 230-2020, and it is recommended to be equipped with an intelligent device with an online monitoring module
2. Quality control points:
- Tenax TA adsorption tube is valid for 4 weeks after activation
- Sampling flow rate control 200-600mL/min
- Formaldehyde absorption liquid needs to be prepared before use
3. Data correction: the sampling volume needs to be converted to the standard state according to the formula V0=V×(273/(t+273))×(P/101.3)

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

CY/T 61-2024 in English
Folding Carton Box Making Process Control Requirements
2024-05-14 -

CY/T 104.2-2014 in English
Graphic technology - Test methods for printability of paper and board Part 2: Basic requirements on printability tester
2014-07-16 -

CY/T 144-2015 in English
Screen printing photosensitive adhesive performance requirements and test methods
2015-12-11