Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
ultrasonic partial discharge tester partical discharge tester introduction analysis general technical specifications technical requirements technical framework pulverized coal bin appendix a a1 pulverized coal delivering duct a2 flue centrifugal blower scopethis standard synthetic waxes
DL/T 1416-2015 in English

DL/T 1416-2015 in English

VALID

General Technical Specifications for Ultrasonic Based Partical Discharge Tester

  • Issued on:2015-04-02
  • Implemented on:2015-09-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $210.00
$204.00
Standard No: DL/T 1416-2015
Document status: VALID
Title in English: General Technical Specifications for Ultrasonic Based Partical Discharge Tester
Title in Chinese: 超声波法局部放电测试仪通用技术条件
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2015-04-02
Implemented on: 2015-09-01
Professional Classification: DL-Electricity
Related Keywords: ultrasonic partial discharge tester
partical discharge tester introduction analysis
general technical specifications
technical requirements
technical framework
Related Topics: electrical tester
Premium Ultrasonic Tester
Instruments for testing ultrasound
Stakeout conditions
Second-hand electroacoustic tester
Wave meter accessories
Ultrasonic method
Ultrasonic impregnator
Wave meter accessories
Ultrasonic Crusher
High pressure ultrasonic instrument
Super Capacitor Tester
Ultrasound+
Ultrasonic instrument model
Ultrasound as
at tester
Ultrasound use
Ultrasonic method
Stakeout conditions
Ultrasonic Instrument Technology
Ultrasonic Instrument Box
Ultrasonic testing equipment
Ultrasonic impregnator
Local discharge instrument
How to use the ultrasonic instrument
Wavefront Tester
How to use the ultrasound machine
Xinyi Super Microwave
Measuring Ultrasonic Frequency
dl/t422-2015
at tester
Ultrasonic working frequency
Ultrasonic synthesizer
Ultrasonic instrument for testing
Used Ultrasonic Equipment
What method is used to test ultrasound
Partial Discharge Test System
Partial enlargement of super-scored papers
dl/t 1416-2015 General technical conditions for ultrasonic partial discharge tester
dl/t 1416-2015


Introduction

Analysis of the technical framework of the standard

This standard systematically specifies the technical requirements for the entire life cycle of the ultrasonic partial discharge tester. The core content covers:

Technical dimensionsKey indicatorsTest methods
Frequency characteristics20kHz-500kHz range10-point frequency sweep test
Sensitivity≥1 (2 times the initial value excitation)Standard sound intensity meter comparison method
Stability4-hour drift Continuous loading test
EMC immunity7 types of electromagnetic compatibility testsGB/T17626 series

Detailed explanation of core performance requirements

4.3.2 Measurement error system

The standard constructs a three-dimensional error evaluation system:

  1. Frequency error: ±20% allowable deviation, which must meet the standard within the range of center frequency ± bandwidth
  2. Amplitude linearity: The deviation does not exceed ±20% within the full range
  3. Dynamic response: The output ratio under 2 times excitation is ≥1

【Application Example】In the detection of a substation, The amplitude deviation of the class=instrument>non-contact sensor measured at a frequency of 300kHz was 18%, which was within the limit but close to the threshold. Annual calibration is recommended.


Key points for implementation of the standard

6.2 Special circumstances for type inspection

  • Targeted testing of relevant items is required when design changes are made
  • Double sampling rule: when one unit fails for the first time, 6 units must be retested
  • Electromagnetic compatibility items must include power frequency magnetic field immunity (Level 4)

Daily operation and maintenance suggestions

PeriodicMaintenance itemsReference clauses
MonthlySensitivity verification4.3.2.3
QuarterlyAmplitude linearity check4.3.2.2
AnnuallyFull set of EMC performance tests4.3.4

Technology evolution analysis

Compared with the earlier versions, the 2015 version has the following major improvements:

  1. Added clear definitions of contact sensors and non-contact sensors
  2. Introduced dBmV as a standardized output unit (zero decibel reference 1mV)
  3. Battery-powered devices have a clear requirement for battery life of ≥5h
  4. MTBF indicator increased to 1000 hours

Sample only — not a preview of DL/T 1416-2015
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend

  • DL/T 790.12-2001 in English

    DL/T 790.12-2001 in English

    Distribution Automation Using Distribution Line Carrier Part 1: General Provisions Part 2: Guidelines for Formulation of Specifications

    2001-12-26
  • DL/T 790.11-2001 in English

    DL/T 790.11-2001 in English

    Distribution Automation Using Distribution Line Carriers Part 1: General Part 1: Architecture of Distribution Automation Systems

    2001-12-26
  • DL/T 646-1998 in English

    DL/T 646-1998 in English

    Technical specification of manufacturing steel transmission pole structures

    1998-03-19