Scope
This section provides a common request/response-oriented data access mechanism that applications from various independent vendors can use in conjunction with DL/T 890.402 to access common information model (CIM) data. It is recommended that applications use this general data access (GDA) service during the initialization process or occasional information synchronization phase. GDA's versatility is reflected in the fact that any application can use it to access any CIM data, and it can also provide a back-end storage mechanism independent of query capabilities, which helps create a CIM data warehouse. This section provides a concise service (GDA service) that meets the functional requirements of current and future applications and can: a) avoid unnecessary complexity; b) does not require any specific database technology for implementation. The GDA Service supports data requests and interactions between applications or systems developed, provided, maintained or operated by independent organizations that interact with applications providing data, and updates to this Service assume that one system does not wish to write directly to another system. To support these goals, GDA functionality is divided into the following three categories: a) read access; b) update access; c) change notification events. It must be noted that the updated part of the GDA service does not support unconditional access to important real-time data. Specifically, the update component allows the application to request changes to data in the service provider, but the service provider is not obligated to perform this change at a specific time. Furthermore, a positive reply from the update service does not mean that the update has occurred, but only that the service provider has successfully received the update request and that the syntax and semantics of the request were correct. Under the assumption of using CIM, GDA can be classified as an enterprise information integration (EII) technology adapter specifically applied to the power industry. City now

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

DL/T 790.51-2002 in English
Distribution automation using distribution line carrier systems -- Part 5-1: Lower layer profiles -- The spread frequency shift keying (S-FSK) profile
2002-04-27 -

DL/T 789-2001 in English
Implementation & acknowledgement of auto-dispatching system rooted in country power network
2001-12-26 -

DL/T 890.1-2007 in English
Energy management system application program interface(EMS-API)-Part 1: Guidelines and general requirements
2007-12-03 -

DL/T 790.31-2001 in English
Distribution automation using distribution line carrier systems -- Part 3: Mains signalling requirements -- Section 1: Frequency bands and output levels
2001-12-26 -

DL/T 5429-2009 in English
Technical code of design for the electric power system
2009-07-22 -

DL/T 860.3-2004 in English
Communication networks and systems in substations -- Part 3: General requirements
2004-03-09 -

DL/T 634.5104-2009 in English
Telecontrol equipment and systems Part 5-104: Transmission protocols - network access for IEC 60870-5-101 using standard transport profiles
2009-07-01 -

DL/Z 790.11-2001 in English
Distribution automation using distribution line carrier systems - Part 1: General considerations - Section 1: Distribution automation system architecture
2001-12-26 -

DL/T 890.405-2009 in English
Energy management system application program interface(EMS-API) Part 405:Generic Eventing and Subscription(GES)
2009-07-01 -

DL/T 890.404-2009 in English
Energy management system application program interface(EMS-API)Part 404:High speed data access(HSDA)
2009-07-01