Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
high voltage electrical installation electrical installation gis electrical installation indoor electrical installation electrical installation project single-cylinder diesel engines ethyl salicylate scopethis standard applies grooved localizer lever
GB 50060-2008 in English

GB 50060-2008 in English

VALID

Code for Design of High Voltage Electrical Installation (3~110kV)

  • Issued on:2008-12-15
  • Implemented on:2009-07-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $80.00
$78.00
Standard No: GB 50060-2008
Document status: VALID
Title in English: Code for Design of High Voltage Electrical Installation (3~110kV)
Title in Chinese: 3~110kV高压配电装置设计规范
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2008-12-15
Implemented on: 2009-07-01
Superseding: GB 50060-1992 Design code for high voltage electrical installation(3~110kv)
ICS Classification: 91.140.50-Electricity supply systems
Chinese Classification: P63-Power supply and distribution engineering
Professional Classification: GB-National Standard
Related Keywords: high voltage electrical installation
electrical installation
gis electrical installation
indoor electrical installation
electrical installation project
Related Topics: Power Design High Voltage
device design
device design
voltage setting
High voltage power distribution
High Voltage Distribution Design
Design of high voltage power distribution device
Power Distribution Unit Design
Preaction device design
High voltage power distribution device
Power distribution device
GB50060
GB50060
GB50060-2008
GB50060-2008
High voltage distribution station
Low-voltage power distribution device and circuit design
Safety Design Code for Calcium Carbide Devices
High voltage complete power distribution device
Standard design of relay room settings
Standard design requirements for relay room settings
High Voltage Motor Specifications
Design and installation of insect-proof net in power distribution room


1.0.1 This code is formulated with a view to make the design of high voltage electrical installation (short for electrical installation) (3~110kV) be safe, economic feasibility, easy access and maintenance and state-of-art technology.
1.0.2 This code is applicable to the designs of construction and extension of high voltage electrical installation project (3~110kV).
1.0.3 As for the design of electrical installation, the equipment shall be adopted and the disposal project shall be established according to the requirements of power load property, capacity, environmental condition and operation, setting, maintenance. The electric installation and material which provided with high efficiency and low energy consumption shall be adopted when the technical economy is logical.
1.0.4 The conjugation of long term and near term is required for the design of electrical installation according to the project character, scale and development planning, and it is required to give priority to the near term, at the same time, the room for extension shall be reserved befittingly.
1.0.5 The principle of optimal land utilization must be adopted in the design of electrical installation.
1.0.6 Not only the requirements stipulated in this code, but also those in the current relevant ones of the nation shall be complied with in the design of electrical installation.

1 General Provisions
2 General Requirements
3 Environmental Conditions
4 Selections of Conductor and Electric Appliance
4.1 General Requirement
4.2 Selection of Conductor
4.3 Selection of Electric Appliance
5 Electrical Installation
5.1 Security Clear Distance in Electrical Installation
5.2 Type Selection of Electrical Installation
5.3 Disposal of Electrical Installation
5.4 Channel and shed in Electrical Installation
5.5 Fire Prevention and Oil-storage Facilities
6 GIS Electrical Installation
7 Requirements of Electrical Installation to Building and Structures
7.1 Requirements of Indoor Electrical Installation to Building
7.2 Requirements of Structures on Outdoor Electrical Installation
7.3 Requirement of Building on Indoor GIS Electrical Installation
Annex A Allowable long-term current-carrying capacity of rectangular aluminum conductor
Annex B Grading standards of line and filth of power plant and transformer substation
Wording Explanations