GB/T 11981-2024 in English
VALIDSteel furring for building
- Issued on:2024-10-26
- Implemented on:2025-05-01
- File Format:PDF
- Delivery:Via email within 5 business days
$359.00
| Standard No: | GB/T 11981-2024 |
| Document status: | VALID |
| Title in English: | Steel furring for building |
| Title in Chinese: | 建筑用轻钢龙骨 |
| Language: | English |
| File Format: | Electronic (PDF) |
| Delivery: | Via email within 5 business days |
| Issued on: | 2024-10-26 |
| Implemented on: | 2025-05-01 |
| Superseding: |
GB/T 11981-2008 Steel furring for building
|
| ICS Classification: | 91.060-Elements of buildings |
| Chinese Classification: | Q73-Metal components and accessories |
| Professional Classification: | GB-National Standard |
| Related Keywords: | light steel keels
light steel keel color-coated steel sheets hot-dip galvanized steel sheets steel |
《GB/T 11981-2024建筑用轻钢龙骨》由TC195(全国轻质与装饰装修建筑材料标准化技术委员会)归口,主管部门为中国建筑材料联合会。
Introduction
GB/T11981-2024 Standard Overview
GB/T11981-2024 "Light Steel Keel for Construction" is an important standard for the construction industry, which comprehensively regulates the classification, technical requirements and test methods of light steel keels. This version of the standard has made many updates to the old version, including terminology adjustment, classification integration and the addition of F-type ceiling keels.
Comparison of major changes
| Old version requirements | New version updates | Impact analysis |
| Delete the definition of terms for keels with different cross-sectional shapes | Add a new classification of F-type ceiling keels | Enriched product variety and improved applicability |
| Requirements for thickness of double-sided galvanized layer | Increased raw material performance requirements | Improve product quality and durability |
| Salt spray resistance test method | Updated to neutral salt spray test, extended to 48 hours | Enhanced anti-corrosion capability verification |
Technical indicators interpretation
The new standard has stricter technical requirements for light steel keels, with the following highlights:
- Raw materials: Hot-dip galvanized steel sheets that meet GB/T2518 or color-coated steel sheets that meet GB/T12754 must be used.
- Dimensional accuracy: Length deviation, section size deviation and thickness tolerance are specified to ensure product consistency.
- Mechanical properties: Static load and impact resistance test requirements for ceiling keel components are added to ensure structural safety.
- Surface rust prevention: The double-sided galvanizing amount is increased to 100g/m², and coating hardness testing is added.
Implementation Suggestions
Actual Application Case:
A construction project adopted the new standard to select light steel keels. By optimizing raw material procurement and strict quality inspection, the durability and safety of the wall and ceiling systems were significantly improved. It is recommended that enterprises:
- Strengthen the inspection of incoming raw materials to ensure compliance with the new standard requirements.
- Update the production process to adapt to the classification and specification changes of new keels.
- Strengthen quality control, especially in mechanical properties and anti-corrosion testing.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.