Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
creepage distances minimum creepage distances creepage distance dimensioning creepage distance maintain minimum insulation resistance annex b adhesive penetration dimethyglyoxime-edta volumetric method scopethis part foreign object damage test
GB/T 16935.5-2008 in English

GB/T 16935.5-2008 in English

VALID

Insulation coordination for equipment within low-voltage systems - Part 5: Comprehensive method for determining clearances and creepage distances equal to or less than 2mm

  • Issued on:2008-07-16
  • Implemented on:2009-04-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $140.00
$136.00
Standard No: GB/T 16935.5-2008
Document status: VALID
Title in English: Insulation coordination for equipment within low-voltage systems - Part 5: Comprehensive method for determining clearances and creepage distances equal to or less than 2mm
Title in Chinese: 低压系统内设备的绝缘配合 第5部分:不超过2mm的电气间隙和爬电距离的确定方法
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2008-07-16
Implemented on: 2009-04-01
ICS Classification: 29.120-Electrical accessories
Chinese Classification: K30-Low voltage apparatus in general
Professional Classification: GB-National Standard
Related Keywords: creepage distances
minimum creepage distances
creepage distance dimensioning
creepage distance
maintain minimum insulation resistance annex b
Related Topics: Voltage spacing
Clearances and creepage distances
Electric clearance Creepage distance
voltage and distance
Creepage distance
Electrical Insulation Coordination in Low-Voltage Systems
GB/T 16935.5
GB/T 16935.5-2008
Insulation coordination of equipment in low voltage system
Electrical clearance
The latest insulation coordination of equipment in low voltage systems

《GB/T 16935.5-2008低压系统内设备的绝缘配合 第5部分:不超过2mm的电气间隙和爬电距离的确定方法》由TC417(全国低压设备绝缘配合标准化技术委员会)归口,主管部门为中国电器工业协会。
GB/T 16935的本部分规定了印制线路板和类似结构件中不超过2mm的电气间隙和爬电距离的尺寸确定方法,在这些结构中,电气间隙和爬电距离相同且均沿着固体绝缘的表面,如第1部分2)中6.2所描述的路径。
本部分只能作为一个整体使用,不允许从本部分中摘选一条或几条使用,也不允许将它们代替第1部分的相应条款来使用。而且本部分只能与第1部分配合使用。
当使用本部分确定电气间隙和爬电距离尺寸时,应采用全部条款代替第1部分给出的相应条款。
对于大于2mm的电气间隙和爬电间隙以及通用的固体绝缘,第1部分适用。


1 Scope and Object

This part of GB/T 16935 specifies the dimensioning of clearances and creepage distances for spacings equal to or less than 2 mm for printed wiring board and equivalent constructions, where the clearance and the creepage distance are identical and are along the surface of solidinsulation, such as the paths described in 6.2 of Part 1 (Examples 1, 5 and 11).

The dimensioning in this standard is more precise than that provided by Part 1. However, if the precision provided by this standard is not required, Part 1 may be applied instead.

This part can only be used in its entirety. It is not permitted to select one or more clauses from this part and to use them in place of the corresponding clauses of Part 1. In addition, this part can only be used together with Part 1.

When this part is applied to the dimensioning of electric clearances and creepage distances, all clauses shall be used in place of the corresponding clauses given in Part 1. For clearances and creepage distances larger than 2 mm, and for solid insulation in general, Part 1 applies.

NOTE 1 The limitation to distances equal to or less than 2 mm applies to basic or supplementary insulation. The total distance of a reinforced or double insulation may be larger than 2 mm.

This part is based on the following criteria for dimensioning:

——minimum clearances independent of the micro-environment (see Table 2);

——minimum creepage distances for pollution degrees 1, 2 and 3 to avoid failure due to tracking (see Table 4);

——minimum creepage distances to avoid flashover across the insulating surface (see Table 5).

Foreword i
Introduction ii
1 Scope and Object
2 Normative References
3 Terms and Definitions
4 Fundamentals of Clearance and Creepage Distance Dimensioning
4.1 Introductory Remark
4.2 Basic Principles
4.3 Voltages and Voltage Ratings
4.4 Frequency
4.5 Time under Voltage Stress
4.6 Pollution
4.7 Information Supplied With the Equipment
4.8 Insulating Material
5 Requirements and Dimensioning Procedures
5.1 General
5.2 Dimensioning of Clearances
5.3 Dimensioning of Creepage Distances
5.4 Requirements for Design of Solid Insulation
6 Tests and Measurements
6.1 Tests
6.2 Measurement of Creepage Distances and Clearances
Annex A (Informative) Dimensioning to Maintain Minimum Insulation Resistance
Annex B (Normative) Water Adsorption Test
Annex C (Informative) Dimensioning Diagrams
Annex D (Informative) Withstand Voltage Test for Creepage Distance under Humid Conditions
Bibliography

Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.