GB/T 17476-1998 in English
SUPERSEDEDSTANDARD test method for determination of additive elements,wear metals,and contaminants in used lubricanting oils and determination of selected elements in base oils by inductively co
- Issued on:1998-08-20
- Implemented on:1999-01-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$175.00
《GB/T 17476-1998使用过的润滑油中添加剂元素、磨损金属和污染物以及基础油中某些元素测定法(电感耦合等离子体发射光谱法)》由TC280(全国石油产品和润滑剂标准化技术委员会)归口,TC280SC1(全国石油产品和润滑剂标准化技术委员会石油燃料和润滑剂分会)执行,主管部门为国家标准化管理委员会。
本标准规定了用电感耦合等离子体发射光谱(ICP-AES)法测定使用过的润滑油中添加剂素、磨损金属和污染物,以及基础油或再生基础油中各种选择金属素含量。
Standard test method for determination of additive elements, wear metals, and contaminants in used lubricating oils and determination of selected elements in base oils by inductively coupled plasma atomic emission spectrometry (ICP-AES)
1 Scope
1.1 This standard covers the determination of additive elements, wear metals, and contaminants in used lubricating oils and the determination of selected metal elements in base oils and re-refined base oils by inductively coupled plasma atomic emission spectrometry (ICP-AES). The specific elements are listed in Table 1 (22 elements including aluminum, boron, barium, calcium, chromium, copper, iron, lead, magnesium, manganese, molybdenum, nickel, phosphorus, potassium, sodium, silicon, tin, silver, sulfur, titanium, vanadium and zinc).
1.2 This standard is applicable to determination of oil-soluble metals and does not purport to quantitatively determine or detect the insoluble particulates. Analytical results are particle size dependent, and low results are obtained for particles larger than a few micrometers. However, the application of this standard can quickly provide information on mechanical wear and the use status of lubricating oil.
1.3 Elements present at concentrations above the upper limit of the calibration curves can be determined with additional, appropriate dilutions and with no degradation of precision.
1.4 For determination of sulfur, the instrument shall have a vacuum or inert-gas optical path. The determination of sodium and potassium is not possible on some instruments having a limited spectral range.
1.5 For elements other than calcium, sulfur, and zinc, the low limits listed in Table 2 and Table 4 were estimated to be ten times the repeatability standard deviation. For calcium, sulfur, and zinc, the low limits represent the lowest concentrations tested in the interlaboratory study.
1.6 This standard involves some dangerous materials, operations and equipment, but it does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and protection practices and determine the applicability of regulatory limitations prior to use.
2 Normative references
The following standards contain provisions which, through reference in this text, constitute provisions of this standard. Unless otherwise specified in the standard, the following normative references shall be the current and valid.
GB/T 4756 Method for manual sampling of petroleum liquids
SH/T 0172 Determination of sulfur in petroleum products (high temperature method)
3 Definitions
For the purposes of this standard, the following definitions apply.
3.1 Babington-type nebulizer
device that generates an aerosol by flowing a liquid through an orifice from which gas flows at a high velocity
3.2 wear metal
metal element introduced into the oil by wear of oil-wetted parts
3.3 contaminant
foreign substance, generally undesirable, introduced into a lubricating oil
Foreword i
ASTM foreword ii
1 Scope
2 Normative references
3 Definitions
4 Summary of test method
5 Significance and use
6 Interferences
7 Apparatus
8 Reagents and materials
9 Preparation of internal standard solution (optional)
10 Sampling and sample handling
11 Preparation of test specimen solutions and standard solutions
12 Preparation of apparatus
13 Calibration
14 Procedure and calculation
15 Report
16 Precision and Bias

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 11134-2025 in English
Determination of kauri-butanol value of hydrocarbon solvents
2025-10-05 -

GB 255-1977 in English
Determination of distillation of petroleum products
1977-01-01 -

GB/T 21791-2008 in English
Determination of ignition temperature of petroleum products
2008-05-12 -

GB/T 29617-2013 in English
Determination of density, relative density,and API gravity of liquids by digital density meter
2013-07-19 -

GB/T 387-1990 in English
Dark petroleum products-Determination of sulphur content-Tubular oven method
1990-12-14 -

GB 8023-1987 in English
Liquid petroleum products; Viscosity; Temperature charts
1987-05-12 -

GB/T 17040-2019 in English
Determination of sulfur in petroleum and petroleum products-Energy dispersive X-ray fluorescence spectrometry
2019-03-25 -

GB/T 4510-2017 in English
Test method for breaking point of bitumen-Fraass method
2017-07-31 -

GB/T 6536-2010 in English
Standard test method for distillation of petroleum products at atmospheric pressure
2011-01-10 -

GB/T 23256-2009 in English
Petroleum liquids - Automatic pipeline sampling - Statistical assessment of performance of automatic samplers determining the water content in hydrocarbon liquids
2009-03-16