Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
metal-sheathed thermocouple cables electrical strength test requirements core standard revision major changes requirements multi-core structure new double-branch/triple-branch structure insulation resistance specification dynamic standard sl16 3-chloroiminodibenzyl introductionthis standard scriew
GB/T 18404-2022 in English

GB/T 18404-2022 in English

VALID

Mineral insulated metal-sheathed thermocouple cables and thermocouples

  • Issued on:2022-10-12
  • Implemented on:2023-05-01
  • File Format:PDF
  • Delivery:Via email within 5 business days
Price(USD): $370.00
$359.00
Standard No: GB/T 18404-2022
Document status: VALID
Title in English: Mineral insulated metal-sheathed thermocouple cables and thermocouples
Title in Chinese: 铠装热电偶电缆及铠装热电偶
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 5 business days
Issued on: 2022-10-12
Implemented on: 2023-05-01
Superseding: GB/T 18404-2001 Mineral insulated thermocouple cables and thermocouples
ICS Classification: 17.200.20-Temperature-measuring instruments
Chinese Classification: N05-Material and component for instrument and meter
Professional Classification: GB-National Standard
Related Keywords: metal-sheathed thermocouple cables
electrical strength test requirements
core standard revision major changes requirements
multi-core structure new double-branch/triple-branch structure
insulation resistance specification dynamic standard
Related Topics: thermocouple
Occasionally
gb t 18404
common dipole
GB/T18404-2001
iec thermocouple
Armored continuous thermocouple cable and armored continuous thermocouple
iec standard thermocouple
iec standard thermocouple
How to Repair a Thermocouple
Thermocouple Repair
Thermocouple Repair
galvanic couple
k-type thermocouple
Crystalline thermocouple
Palladium Alloy Thermocouple
Armored cable
surface thermocouple
dipole dipole
Heating plate heating mantle
Heating plate heating mantle
Coupling surface
Armored Continuous Thermocouple
Thermocouple subzero
Azulene dipole
Thermocouple Function
GBT18404
GB/T 18404-2001
GB/T 18404-2022
Thermocouple measuring range
Thermocouple Principle
Cable armor
Armoured
Armored heating
Armored thermocouple cable and armored thermocouple
Armored RTD Execution
Thermocouple classification
Thermocouple Requirements
Thermocouple abnormality
Armored Thermocouple Accuracy Class
Armored thermal resistor
Armored control cable grounding
Galvanic current test
Armored Thermocouple Insulation Resistor
Standard Thermocouple Wholesale
Thermal resistance and thermocouple wiring method
Armored cable grounding
Thermocouple Germany
Thermocouple welding method
Armored thermal resistance national standard
Thermocouple test
The correct way to connect a thermocouple
thermocouple military
gb18404
gb/t 18404
gb/t 18404-2022
gbt18404
gb/t18404-2022
gbt18404-2022
Industrial armored thermal resistor
gb/t18404

《GB/T 18404-2022铠装热电偶电缆及铠装热电偶》由TC419(全国仪表功能材料标准化技术委员会)归口,主管部门为中国机械工业联合会。


Introduction

Interpretation of the key points of the core standard revision

Major changes Requirements of the 2016 version Requirements of the 2001 version
Expansion of multi-core structure New double-branch/triple-branch structure Only single-branch structure is allowed
Insulation resistance specification Dynamic standard for classification in Tables6-7 Fixed numerical limit

Key material technical specifications

According to Chapter 4, the materials of qualified casing are:

  • 304 stainless steel: Ra≤3.2μm
  • High purity magnesium oxide insulation: Purity ≥96%

Typical outer diameter specification comparison:

Structural type Standard outer diameter (mm) Casing wall thickness (mm)
Single branch 1.5/3.0/6.0 0.15-1.08
Double branch 3/6.4/8.0 0.14-0.97

Electrical test standards

According to the electrical strength test requirements in Table 5:

  • For bushing>3.2mm
    DC test voltage: 500V±5%
  • Grounded measuring terminal
    Head welding thickness: 0.1D~0.8D