Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
indoor air quality indoor air quality indicators indoor air quality indicators annex b indoor air quality indicator indoor air quality chinastandards.net composite organic halogen detection system alcohol solutions development reports
GB/T 18883-2022 in English

GB/T 18883-2022 in English

VALID

Standards for indoor air quality

  • Issued on:2022-07-11
  • Implemented on:2023-02-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $630.00
$612.00
Standard No: GB/T 18883-2022
Document status: VALID
Title in English: Standards for indoor air quality
Title in Chinese: 室内空气质量标准
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2022-07-11
Implemented on: 2023-02-01
Superseding: GB/T 18883-2002 Indoor air quality standard
ICS Classification: 13.040.01-Air quality in general
Chinese Classification: C51-Environmental sanitation
Professional Classification: GB-National Standard
Related Keywords: indoor air quality
indoor air quality indicators
indoor air quality indicators annex b
indoor air quality indicator
indoor air quality chinastandards.net
Related Topics: air quality
European Indoor Air
European Indoor Air Standards
din indoor air standard
internal standard internal standard
Indoor Air Quality Standards
MS standard gas
air quality standard
iso indoor air quality
Indoor Air Benzene Series
Indoor Air Butene
zero air quality
Factory Indoor Air Quality
temperament
Indoor Air Total Hydrocarbons
air mass flow rate
Ammonia Air Quality
laboratory air quality
Air Standard Mass Spectrometry
air mass flow rate
voc standard room air
How much is the voc standard indoor
Indoor air voc content
Indoor air voc content
How much is the voc standard indoor
voc standard indoor
VOC content in indoor air
Indoor air voc content
indoor air quality
Indoor Air Quality Meter
air quality?
air quality.
Indoor Air Quality Maintenance
Indoor air quality standard pm2.5
laboratory air quality
indoor air quality iso
indoor oxygen content
copper mass in air
Air quality
Indoor Standard D-Series
standard air density
Development of indoor air at home and abroad
standard air density
air quality not up to standard
voc standard indoor
Indoor Air Quality Standards 2017
Air content in liquid
temperament
air standard substance
gb18883
carrier air
Indoor Air Quality Analysis
Air quality up to standard
air quality water quality
How to maintain indoor air
a3 type indoor quality detector
Air standard
air quality and air quality
Internal standard measurement
National Indoor Air Quality
Air quality at home and abroad
Indoor Air Index
lead in air
Quality gas
indoor air place
chamber + air
air quality g1
Indoor Benzene Content
air quality plant
vocs standard indoor
vocs standard indoor
Indoor ammonia content
Indoor air quality g1 and g2
Air quality standard pm2.5
Indoor air quality pm2.5
indoor air benzene
Indoor Air Xylene
Indoor air quality standard benzene
Indoor index of benzene
Indoor air quality testing
indoor air methanol
Indoor Air Quality Report
indoor air convection machine
Indoor Air Quality Conditions
Indoor Air Quality Treatment
standard zero air
Indoor gas is
Indoor Air Quality Analyzer
indoor air quality definition
indoor air value
Indoor testing standard chemical substances
pm indoor air in various countries
indoor air pm10
Benzene content in indoor air
Batch testing of indoor air
indoor air bacteria
Indoor air quality qualified
Indoor and Outdoor Air Quality
Efficient Indoor Air Features
Air Quality by Province
Air Quality by Province
Indoor air quality standard pm2.5
Indoor chlorine content
indoor oxygen content
internal measurement blank
Air Quality by Province in 2017
indoor oxygen content
Air Quality 2013
Which 6 items are tested for indoor air quality
Who Controls Indoor Air Quality
Indoor toc content
Formaldehyde Indoor Air Quality
Internal and external air quality monitoring
Aerosol chamber
Air indoor standard ppb
Air standard
Benzene air quality standard
Indoor air quality detection method
"air quality
Indoor water quality testing
Check indoor air quality
Indoor and outdoor air quality monitoring
Indoor ambient air quality monitoring
Indoor Air Quality Analysis System
Flow indoor quality control
Air quality up to standard
Indoor Air Monitoring
Air quality instruments at home and abroad
Outdoor Air Quality Testing
aircraft interior air quality
Indoor Air Quality*
"Indoor Air Quality Standards"
Indoor S content
Indoor air quality abroad
GB/T18883-2002
GBT18883
GBT18883
GB/T 18883-2002
GB/T 18883-2022
Indoor Air Parameters
indoor air
Outdoor air quality monitoring
gdyk indoor air quality
GC-MS internal standard
quality standards laboratory
The abscissa of the temperament standard curve
EU air quality
air quality standard acetone
Domestic quality standards laboratory
Are there air quality standards for hydrogen fluoride?
Air Toxic Substances Quality StandardMolybdenum
Is hydrocarbon-free air standard air?
EU indoor air quality
Indoor air quality standards replaced
National quality standards laboratory
Parameters of air quality index standard table
How to add internal standard to standard gas
Mo Air Quality
Gas phase internal standard method standard curve
Standard air viscosity
Internal standard quantitative standard curve production
air quality standards japan
gb18883-2022
gb/t18883-2022
gbt18883-2022
zinc air quality
gb 18883-2022
gb/t18883
gb/t 18883-2022
Air quality monitoring standard station
gb18883-2022tvoc
gb/t 18883-2020
high pressure air quality
Contents of API Quality Standards
Indoor quality control standard operating documents
Are there air quality standards for propylene?
gb/t 18883-
National Indoor Air Quality Testing

《GB/T 18883-2022室内空气质量标准》由361(国家卫生健康委员会)归口,主管部门为国家卫生健康委员会。


ChinaStandards.net is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative.

This document is developed in accordance with the rules given in GB/T 1.1-2020 Directives for standardization - Part 1: Rules for the structure and drafting of standardizing documents.

This document replaces GB/T 18883-2002 Indoor air quality standard. In addition to structural adjustments and editorial changes, the following main technical changes have been made with respect to GB/T 18883-2002:

a) four terms, i.e., “fine particulate matter”, “1-hour average”, “8-hour average” and “24-hour average”, and their definitions, are added (see 3.3, 3.5~3.7); the term “normal state” and its definition is deleted (see 3.4 of Edition 2002); three terms, i.e., "indoor air quality indicator", "inhalable particulate matter" and "total volatile organic compounds", and their definitions, are modified (see 3.1, 3.2 and 3.4; 3.1~3.3 of Edition 2002);

b) three indicators, i.e., trichloroethylene, tetrachloroethylene and fine particulate matter, and their requirements are added (see 4.2);

c) the "air flow rate" is changed to "air velocity" (see 4.2; 4.2 of Edition 2002);

d) the "air conditioning in summer" and "heating in winter" in remarks on temperature, relative humidity and air velocity are changed to "summer" and "winter" respectively (see 4.2; 4.2 of Edition 2002);

e) the "total number of colonies" is changed to "total bacterial count" (see 4.2; 4.2 of Edition 2002);

f) the requirements of seven indicators, i.e., nitrogen dioxide, carbon dioxide, formaldehyde, benzene, inhalable particulate matter, total bacterial count and radon, are modified (see 4.2; 4.2 of Edition 2002);

g) the radon control requirements are modified, and the "action level" is changed to the "reference level" (see 4.2; 4.2 of Edition 2002);

h) technical contents such as environmental requirements, sample transportation and preservation, parallel sample inspection, result expression and laboratory safety are added (see A.2.1, A.7, A.9.4, A.10.2 and A.11 in Annex A);

i) the determination methods and method sources of 11 indicators, i.e., temperature, relative humidity, air velocity, fresh air volume, ozone, nitrogen dioxide, sulfur dioxide, carbon dioxide, carbon monoxide, ammonia and formaldehyde (spectrophotometry), are modified; the determination methods and method sources of trichloroethylene, tetrachloroethylene and fine particulate matter are added; the recommended sampling method parameters are added (see Annex A; Annex A of Edition 2002);

j) the determination methods of 5 indicators, i.e., formaldehyde (high performance liquid chromatography), benzo[a]pyrene, inhalable particulate matter, fine particulate matter and radon, are added (see Annexes B, E, F and H), and those of benzene, total volatile organic compounds (TVOC) and total bacterial count are modified (see Annexes C, D and G; Annexes B~D of Edition 2002).

Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. The issuing body of this document shall not be held responsible for identifying any or all such patent rights.

This document was proposed by and is under the jurisdiction of the National Health Commission of the People's Republic of China.

The previous editions of this document are as follows:

——it was firstly released as GB/T 18883-2002 in 2002;

——this is the first revision.


Standards for indoor air quality

1 Scope

This standard specifies the physical, chemical, biological and radioactive indicators and requirements of indoor air quality, and describes the measurement methods of the indicators.

This standard is applicable to residential and office buildings, and may apply to other indoor environment by reference.

2 Normative references

The following documents contain provisions which, through reference in this text, constitute provisions of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

GB 3095–2012 Ambient air quality standard
GB/T 12372 Standard method for examination of nitrogen dioxide in air of residential areas-Modified Saltzman method
GB/T 14669 Air quality. Determination of ammonia. Ion selective electrode method
GB/T 15435 Ambient air - Determination of nitrogen dioxide - Saltzman method
GB/T 16128 Standard method for hygienic examination of sulfur dioxide in air of residential areas - Formaldehyde solution sampling-pararosaniline hydrochloride spectrophotometric method
GB/T 16129 Standard method for hygienic examination of formaldehyde in air of residential areas - Spectrophotometric method
GB/T 18204.1 Examination methods for public places - Part 1: Physical parameters
GB/T 18204.2 Examination methods for public places - Part 2: Chemical pollutants
GB/T 27476.5 Safety in testing laboratories - Part 5: Chemical aspects
GB/T 32465 Requirements for verification & validation of detection methods and internal quality control on chemical analysis
HJ 93 Specifications and test procedures for PM10 and PM2.5 sampler
HJ/T 167 Technical specification for monitoring of indoor air quality
HJ 533 Air and exhaust gas - Determination of ammonia - Nessler’s reagent spectrophotometry
HJ 590 Ambient air - Determination of ozone - Ultraviolet photometric method

3 Terms and definitions

For the purposes of this document, the terms and definitions given in GB 3095 - 2012 and the following apply.

3.1
indoor air quality indicator
physical, chemical, biological and radioactive indicators in indoor air related to human health

3.2
inhalable particulate matter; PM10
particulate matter floating in the air, with particle size (aerodynamic equivalent diameter) less than or equal to 10μm

[Source: GB 3095-2012, 3.3, modified]

3.3
fine particulate matter; PM2.5
particulate matter floating in the air, with particle size (aerodynamic equivalent diameter) less than or equal to 2.5μm

[Source: GB 3095-2012, 3.4, modified]

3.4
total volatile organic compounds; TVOC
volatile organic compounds with retention time between n-hexane and n-hexadecane when sampled by Tenax TA or equivalent filling adsorption tube and analyzed with a non-polar or weak-polar capillary column (polarity index: <10)

3.5
1-hour average
arithmetic average of pollutant concentration in any 1 hour

[Source: GB/T 3095- 2012, 3.8]

3.6
8-hour average
arithmetic average of pollutant concentration in consecutive 8 hours

[Source: GB 3095-2012, 3.9, modified]

3.7
24-hour average
arithmetic average of pollutant concentration in consecutive 24 hours

[Source: GB 3095-2012, 3.10, modified]

4 Requirement for indoor air quality

4.1 Indoor air shall be non-toxic, harmless and have no abnormal smell.

4.2 Indoor air quality indicators and requirements shall comply with the provisions of Table 1.

Foreword i
1 Scope
2 Normative references
3 Terms and definitions
4 Requirement for indoor air quality
5 Determination and evaluation of indoor air quality indicators
Annex A (Nominative) Technical guideline for detection of indoor air quality indicators
Annex B (Nominative) Determination of formaldehyde
Annex C (Normative) Determination of benzene, methylbenzene and xylene
Annex D (Normative) Determination of total volatile organic compounds (TVOC)
Annex E (Normative) Determination of benzo[a]pyrene in inhalable particulate matter
Annex F (Normative) Determination of inhalable particulate matter and fine particulate matter
Annex G (Normative) Determination of total bacterial count
Annex H (Normative) Determination of radon
Bibliography