VALIDTest guide for instrument transformers―Part 2:Inductive voltage transformers
- Issued on:2017-12-29
- Implemented on:2018-07-01
- File Format:PDF
- Delivery:Via email within 5 business days
$728.00
《GB/T 22071.2-2017互感器试验导则 第2部分:电磁式电压互感器》由TC222(全国互感器标准化技术委员会)归口,主管部门为中国电器工业协会。
Introduction
Analysis of the core content of the standard
| Test categories | Key items | Technical changes (vs 2008 version) |
|---|---|---|
| Type test | Temperature rise test, impulse withstand voltage, accuracy verification | New requirements for 750kV/1000kV equipment |
| Routine test | Partial discharge, dielectric loss, sealing | Optimized test sequence flow chart |
| Special test | Mechanical strength, internal arc fault | Specify the test methods for GIS equipment |
Detailed explanation of key technical requirements
Key indicators of temperature rise test
The test voltage needs to be selected according to the rated voltage factor:
- 1.2 times the rated voltage (steady state)
- 1.9 times the rated voltage (continuous 8h)
- 1.5/1.9 times the rated voltage (30s transient)
The allowable temperature rise value needs to be corrected for altitude according to Table 4, and it needs to be reduced by 0.4%-0.5% for every 1000m above sea level
Recommendations for the implementation of the standard
Requirements for test equipment selection
| Equipment type | Accuracy requirements |
|---|---|
| Partial discharge instrument | ≥100kHz bandwidth, 5pC sensitivity |
| Dielectric loss tester | 0.001% resolution |
Special note: 750kV and above equipment requires a dedicated shielded test environment
Comparison between the old and new standards
Main updates of the 2017 version:
- Add test requirements for system nominal voltage 750kV/1000kV
- Improve test sequence logic (add flow chart in Figure 1)
- Supplement special test clauses for gas-insulated products
- Clarify insulation verification requirements before and after short-circuit tests

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/Z 1094.20-2026 in English
Power transformers—Part 20:Energy efficiency
2026-07-02 -

GB/T 10228-2023 in English
Technical parameters and requirements for dry-type power transformers
2023-05-23 -

GB/T 32825-2024 in English
Technical parameters and requirements for three-phase dry-type tridimensional wound core power transformers
2024-12-31 -

GB/T 1094.7-2024 in English
Power transformers—Part 7: Loading guide for mineral-oil-immersed power transformers
2024-11-28 -

GB/T 6451-2023 in English
Technical parameters and requirements for oil-immersed power transformers
2023-09-07