GB/T 22082-2024 in English
VALIDReinforced concrete segments
- Issued on:2024-10-26
- Implemented on:2025-05-01
- File Format:PDF
- Delivery:Via email within 5 business days
Price(USD):
$510.00
$495.00
$495.00
| Standard No: | GB/T 22082-2024 |
| Document status: | VALID |
| Title in English: | Reinforced concrete segments |
| Title in Chinese: | 预制混凝土衬砌管片 |
| Language: | English |
| File Format: | Electronic (PDF) |
| Delivery: | Via email within 5 business days |
| Issued on: | 2024-10-26 |
| Implemented on: | 2025-05-01 |
| Superseding: |
GB/T 22082-2017 Reinforced concrete segments
|
| ICS Classification: | 91.100.40-Products in fibre-reinforced cement |
| Chinese Classification: | Q14-Concrete product |
| Professional Classification: | GB-National Standard |
| Related Keywords: | concrete segments introduction core changes
concrete ≤3.0kg/m³ perform durability verification test concrete strength subway tunnel alkali-resistant glass fiber/basalt fiber durability index chloride ion content classification fiber material steel/synthetic fiber |
| Related Topics: | precast concrete
GBT22082 |
《GB/T 22082-2024预制混凝土衬砌管片》由TC197(全国水泥制品标准化技术委员会)归口,主管部门为中国建筑材料联合会。
Introduction
Core changes in the standard revision
| Revision dimensions | 2017 version | New content in the 2024 version |
|---|---|---|
| Sectional shape | Circular/rectangular/irregular | Added rectangular (LJ) classification |
| Fiber material | Steel/synthetic fiber | Added alkali-resistant glass fiber/basalt fiber |
| Durability index | Chloride ion content ≤0.1% | Added 28d chloride ion permeability coefficient ≤4×10⁻¹²m²/s |
Key technical requirements for segments
1. Material specifications
Cement must meet the requirements of GB175, with alkali content ≤0.6%; the maximum particle size of coarse aggregate ≤31.5mm; the newly added basalt fiber application must comply with GB/T23265.
2. Production process control
- Demolding strength: vacuum suction cup ≥15MPa, other methods ≥20MPa
- Repair standard: crack width <0.20mm, surface defect ≤5% area
Typical engineering application data
| Project type | Representative specifications (mm) | Concrete strength |
|---|---|---|
| Subway tunnel | 5500×1500×350 | C50 and above |
| Integrated pipeline corridor | 3000×1000×250 | P10Impermeability |
Implementation suggestions
Corrosive environment response plan
Coastal area project suggestions:
- Use alkali-resistant glass fiber for reinforcement
- Total alkali content of concrete ≤3.0kg/m³
- Perform durability verification test according to GB/T50082
Key points of quality control
- Horizontal assembly inspection: circumferential joint gap ≤2mm
- Leakage test: 0.6MPa water pressure constant pressure for 2h without leakage
- Pulling resistance of lifting hole ≥5 times the deadweight of the segment
Sample only — not a preview of GB/T 22082-2024

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 45594-2025 in English
Test methods for the properties of non-structural ultra-high performance concrete component
2025-04-25 -

GB/T 9772-2009 in English
Fiber cement corrugated sheets and ridge tile
2009-03-09