GB/T 23265-2023 in English
VALIDChopped basalt fiber for cement concrete and mortar
- Issued on:2023-05-23
- Implemented on:2023-12-01
- File Format:PDF
- Delivery:Via email within 5 business days
$447.00
《GB/T 23265-2023水泥混凝土和砂浆用短切玄武岩纤维》由TC197(全国水泥制品标准化技术委员会)归口,主管部门为中国建筑材料联合会。
Introduction
Background of Standard Revision and Technological Evolution
This revision is the first major update of GB/T 23265 standard since its first release in 2009, which mainly reflects the three development stages of basalt fiber application technology:
| Technical stage | Features of 2009 version | Improvements of 2023 version |
|---|---|---|
| Performance indicators | Focus on basic mechanical properties | Added durability indicators such as bending toughness and impact strength ratio |
| Test methods | 6 basic tests | 5 normative appendices added, the test system is more complete |
| Application classification | Single function classification | Refined into two categories: crack prevention and crack resistance (BF/BSF) and toughening and reinforcement (BZ) |
Analysis of core technical requirements
4.1 Product classification system
The standard establishes a three-dimensional classification matrix:
- Fiber morphology: original yarn bundle (S type) and plied yarn (T type)
- Application scenarios: concrete (BF/BZ) and mortar (BSF)
- Functional positioning: crack prevention and crack resistance and toughening and reinforcement
6.3 Key performance indicators
Typical case: When BZ fibers are used in a bridge project, their tensile strength must be ≥1500MPa, elastic modulus ≥35GPa, and the strength retention rate must still remain above 65% after alkali treatment.
| Core Index Comparison | S-type fiber | T-type fiber | |
|---|---|---|---|
| Mechanical properties | Tensile strength | ≥1250MPa | ≥1250MPa |
| Elastic modulus | ≥30GPa | - | |
| Elongation at break | ≤5.0% | ||
| Alkali resistance | ≥50% | ≥65% | |
Implementation points and engineering suggestions
Principles of material selection
- Length matching: 12-30mm fiber for concrete, 3-15mm for mortar
- Diameter control: single filament diameter deviation ≤±10%, twisted yarn acceptance according to the indicated value
- Dosage optimization: refer to the manufacturer's recommendation, usually 0.5-2kg/m³
Construction quality control
Common problems: Insufficient mixing time caused fiber agglomeration in a subway project, which was later adjusted to the process of dry mixing for 30 seconds + wet mixing for 90 seconds, which significantly improved the dispersion uniformity.
Acceptance inspection process
| Inspection type | Item | Sampling quantity | Judgment basis |
|---|---|---|---|
| Factory inspection | 5 items such as appearance and size | 1kg/batch | Chapter 6 Basic requirements |
| Type inspection | All items inspection | S type 2kg, T type 10kg | Technical consistency verification |
Test method innovation
The 5 newly added normative appendices in the standard constitute a complete test system:
- Appendix A: Tensile test of plied yarn class=instrument>Pattern reinforcement method, solve the problem of short fiber clamping
- Appendix E: Using Energy absorption value to evaluate bending toughness, which is more in line with engineering practice
- Appendix C/D: 80℃ alkali solution accelerated aging method to simulate long-term durability
Test points: During the alkali resistance test, it is necessary to pay attention to the pH value of the cement clear solution should be ≥12.5, and it needs to be fully rinsed with distilled water after soaking to avoid the influence of residual alkali.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 38143-2019 in English
Alkali-resistant glass fibres for cement concrete and mortar
2019-12-10