GB/T 27432-2025 in English
VALIDTechnical specifications for remote assessment of laboratory
- Issued on:2025-02-28
- Implemented on:2025-02-28
- File Format:PDF
- Delivery:Via email within 1~3 business days
$262.00
《GB/T 27432-2025实验室远程评审技术规范》由TC261(全国认证认可标准化技术委员会)归口,主管部门为国家标准委。
Introduction
Standard Framework and Technology Evolution
As the first special standard for remote laboratory review in my country, this specification marks an important transformation from the traditional on-site review mode to digital review. The standard is compiled based on the application background of new technologies such as 5G communication and cloud computing, and refers to the requirements of six international documents such as IAF MD 4:2018.
Analysis of core review principles
| Principles | Technical requirements | Implementation cases |
|---|---|---|
| Convenience and equivalence | It is necessary to ensure that the conclusions of remote review are equivalent to those of on-site review | The high-altitude laboratory uses 360° panoramic camera to achieve environmental verification |
| Information security | Complies with the encrypted transmission requirements of YD/T1737 | Use the national secret algorithm SM4 to encrypt video streams |
| Risks are controllable | Establish a three-level risk warning mechanism | Initiate emergency plan when network delay > 200ms |
Detailed explanation of ICT technical requirements
Hardware configuration standards
The specification clearly requires that the camera resolution be ≥ 1.3 million pixels (1280×960dpi). In actual applications, it is recommended to use a 4K pan-tilt camera in combination with a sound pickup array to clearly capture the details of the experimental operation.
Software Function Matrix
- Basic functions:Video conferencing (support ≥3-party access), screen sharing, file transfer
- Enhanced functions:Experimental process marking (timestamp positioning), multi-view switching, digital watermark
Key nodes of the implementation process
- Pre-debugging phase:Bandwidth test (≥50Mbps) and equipment compatibility verification need to be completed
- Technical capability confirmation:Adopt "dual-channel verification" mode (real-time video + process recording)
- Evidence preservation:Electronic materials need to retain original metadata, and the storage period is ≥3 years
Risk prevention and control implementation suggestions
For common risk scenarios, it is recommended to establish:
| Risk type | Prevention and Control Measures | Detection Indicators |
|---|---|---|
| Data Tampering | Blockchain Evidence Storage Technology | Hash Value Verification Matching Rate 100% |
| Identity Impersonation | Dynamic Iris Recognition | Biometric False Recognition Rate≤0.001% |
| Network Interruption | 5G/WiFi6 Dual-Link Backup | Switching Delay≤300ms |

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/Z 27426-2022 in English
Guidance on monitoring validity of the results for chemical analysis laboratory
2022-10-12 -

GB/T 27060-2025 in English
Conformity assessment—Code of good practice
2025-02-28 -

GB/T 22275.8-2026 in English
Requirements of conduct for good laboratory practice—Part 8: The application of cloud computing used in GLP laboratory
2026-05-25 -

GB/T 22272-2008 in English
Advisory document for good laboratory practice : Establishment and control of archives that operate in compliance with the principles of GLP
2008-08-04 -

GB/T 27011-2019 in English
Conformity assessment—Requirements for accreditation bodies accrediting conformity assessment bodies
2019-12-31