Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
test method test methods test apparatus test specimen test procedures twelve-point wrenches closing system introduction interpretation equipment function scopethis standard
GB/T 29555-2013 in English

GB/T 29555-2013 in English

VALID

Test method of operating forces for doors

  • Issued on:2013-07-19
  • Implemented on:2014-03-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $120.00
$117.00
Standard No: GB/T 29555-2013
Document status: VALID
Title in English: Test method of operating forces for doors
Title in Chinese: 门的启闭力试验方法
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2013-07-19
Implemented on: 2014-03-01
ICS Classification: 91.060.50-Doors and windows
Chinese Classification: P32-Building construction and decoration engineering
Professional Classification: GB-National Standard
Related Keywords: test method
test methods
test apparatus
test specimen
test procedures
Related Topics: GB/T 29555
force test
gb/t+29555
Box door closing test method
start
GBT29555
GB/T 29555-2013
Door opening and closing force test method
Sealing performance test methods and contents of airtight doors (windows)
Eyes closed and upright test method
gb 29555

《GB/T 29555-2013门的启闭力试验方法》由333(住房和城乡建设部)归口,TC448(全国建筑幕墙门窗标准化技术委员会)执行,主管部门为住房和城乡建设部。
本标准规定了测定门的开启和关闭,用钥匙或执手锁闭和打开五金配件所需作用力的试验方法。
本标准适用于手动操作的带锁闭装置的平开和推拉开启形式的人行门。
本标准不适用于装有自动关闭装置的门的关闭力的测量,也不适用于装有特殊五金配件如紧急开启装置的门。


1 Scope

This standard defines the test methods to determine the forces to open/close doors and to lock/unlock the hardware using a key or handle.

It is only applicable to side-hung and sliding doors with latches in manual operation, for pedestrian use.

The measurement of forces for doors with self-closing devices engaged is excluded from this test method. It is also not applicable to doors with special hardware e.g. emergency exit devices.

Note: The operation of some windows involves latches and may be tested in accordance with this standard.

2 Normative References

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

GB/T 5823–2008 Terminology for Building Windows and Doors


3 Terms and Definitions

For the purposes of this standard, the terms and definitions given in GB/T 5823–2008 and the following apply.

3.1

attachment point

a point adjacent to a single handle. With more than one handle, a point midway between the extreme handle positions

4 Principle of Test

The principle consists of measuring the minimum force or torque required to lock or unlock the hardware, (locks, handles etc.), commence opening and complete closing of the sliding or side-hung door leaf to the latched position or locking of all safety devices.

Foreword i
1 Scope
2 Normative References
3 Terms and Definitions
4 Principle of Test
5 Test Apparatus
6 Test Specimen
7 Procedure for Basic Operation
8 Test Procedures
9 Expression of Results
10 Test Report
Annex A (Informative) Typical Set-up Mode for Side-hung Door
Annex B (Informative) Typical Set-up Mode for Sliding Door