Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
key safety features safety dimension ordinary oxygen bomb calorimeter intelligent oxygen bomb oxygen bomb calorimeter safety standard oxygen bomb pressure test oxygen bomb equipment-oxygen bomb calorimeter introduction core requirements tube sheet heat exchangers scopethe types alloy tool steel plate lung diseases
GB/T 32707-2016 in English

GB/T 32707-2016 in English

VALID

Safety requirements for laboratory instrument and equipment-Oxygen bomb calorimeter

  • Issued on:2016-06-14
  • Implemented on:2017-01-01
  • File Format:PDF
  • Delivery:Via email within 5 business days
Price(USD): $810.00
$786.00
Standard No: GB/T 32707-2016
Document status: VALID
Title in English: Safety requirements for laboratory instrument and equipment-Oxygen bomb calorimeter
Title in Chinese: 实验室仪器及设备安全规范 氧弹式热量计
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 5 business days
Issued on: 2016-06-14
Implemented on: 2017-01-01
ICS Classification: 31.040.10-Fixed resistors
Chinese Classification: A54-Thermal Measurement
Professional Classification: GB-National Standard
Related Keywords: key safety features safety dimension ordinary oxygen bomb calorimeter intelligent oxygen bomb
oxygen bomb calorimeter safety standard
oxygen bomb pressure test
oxygen bomb
equipment-oxygen bomb calorimeter introduction core requirements
Related Topics: The high quality of the bomb calorimeter
A Better Bomb Calorimeter
State-of-the-art bomb calorimeter
What are the oxygen bomb calorimeters?
Oxygen bomb calorimeter high quality
Laboratory small equipment
Dioxygen laboratory equipment
Experimental complete set of equipment
Organic Lab Design
calorimeter bomb
Oxygen Laboratory Equipment
Post-holiday laboratory instruments
equipment
that equipment
equipment
laboratory thermal imager
Experimental Instruments and Reagents
Various laboratory instruments
Instruments and equipment
Safety Specifications for Laboratory Instruments and Equipment Balance Instruments
Acceptance of instruments and equipment
Oxygen Bomb Calorimeter
Oxygen Bomb Calorimeter
Biological instruments and equipment
Laboratory equipment group
Domestic Laboratory Safety
Oxygen bomb
Installation Design Lab
Biochemical instruments and equipment
Laboratory series instruments
flow laboratory instrument
Design of various instruments and equipment
Laboratory series instruments
Instrument and equipment design
Used Laboratory Instruments
Measuring instruments and equipment
Beijing instrument equipment
Laboratory Measuring Instruments
laboratory calorimeter
Full instrument
Measuring instruments and equipment
Small instrument laboratory equipment
calorimeter instrument
calorimeter instrument
Thermal Conductivity Meter Design
Instrument Design Safety
Second-hand laboratory equipment
Instrument and equipment design
Laboratory Meter
bomb calorimeter
Heating instrument laboratory equipment
Laboratory version instrument
Thermal Conductivity Meter Design
flow laboratory equipment
Instrument Calorimeter
Laboratory Instrument System
Oxygen Bomb Calorimeter
Instrument case design
Steel Laboratory Instruments
Laboratory Environment Safety Equipment
laboratory security data security
Laboratory design and installation
Laboratory instrument installation
Oxygen Equipment
Laboratory Instrument Maintenance
Laboratory Instrument Safety
Laboratory heater
Laboratory shared equipment
Acceptance of measuring instruments and equipment
Laboratory instruments and equipment safety
Oxygen bomb
Laboratory Spring Festival Safety
calorimeter experiment
Equipment range
Calorimeter + Experiment
Oxygen Bomb Calorimeter
laboratory specifications and
Instrument laboratory design
calorimeter test
laboratory calorimeter
Design instrument installation
Metering equipment
Instrumentation and test equipment
p3 laboratory instrument
Oxygen Bomb Oxygen Meter
Intermediate Instrument Lab
2. Experimental instruments and equipment
2. Experimental instruments and equipment
Oxygen Bomb Automatic Calorimeter
2. Experimental equipment
2. Experimental equipment
Experimental Instruments and
Calculation and Measuring Instruments
Oxygen bomb calorific value meter
Oxygen bomb calorific value
Laboratory Instrument Quality
Laboratory Safety Abroad
Instruments and Test Equipment
Instruments and materials
Test equipment and instruments
2. Experimental instruments and equipment
Generation Laboratory Design
Laboratory large instruments and equipment
Laboratory large instruments and equipment
Instrumentation and equipment
Laboratory Instrument and Equipment Safety
laboratory equipment
Baidu Security Lab
Measuring equipment and instruments
Oxygen instrument
Foreign laboratory design
Various laboratory equipment
Equipment Safety
Measurement and control instruments and equipment
laboratory equipment instrument laboratory equipment
local instrumentation design
Steel Laboratory Instruments
Oxygen Bomb Automatic Calorimeter
The main equipment of the laboratory
Experimental Instruments and Equipment
Materials Laboratory Design
Public Safety Equipment Instruments
some lab instruments
Calorimeter Laboratory
oxygen laboratory
p3 laboratory equipment
unsafe instrument
Pre-lab Instruments
How to design a flow laboratory
Calorimetry Laboratory
Three experimental instruments and equipment
Laboratory installation design
Special laboratory equipment installation
p3 laboratory instrument
Calorimeters and Calorimeters
Instrument laboratory instrument laboratory equipment
oxygen laboratory
GBT32707
GB/T 32707-2016
Laboratory safety equipment and facilities
Quantum optics laboratory experimental instruments
Laboratory safety facilities
Principle of oxygen bomb calorimeter
Basic principles of oxygen bomb calorimeter
What are the laboratory safety equipment?
Animal P3 laboratory instruments and equipment
Calorimeter equipment
Calorimeter experimental conditions
Laboratory safety tips
Laboratory design specifications and standards, gb20346
Experimental instrument and equipment manufacturers
Food safety laboratory specifications and
The latest national standard laboratory design specifications
oxygen bomb calorimeter
Manufacturing and acceptance of experimental equipment and instrument products
Laboratory gas cylinder room design safety
Manufacturing standards for experimental instruments and equipment
Acceptance of laboratory instrumentation and equipment
Is the laboratory safe?
Laboratory fire protection design
Laboratory instrument preheating requirements
Biosafety laboratory airtight design
Mass spectrometry laboratory design
Pharmacology laboratory design
Foreign laboratory safety
Classification of laboratory instruments and equipment
American laboratory equipment
Oxygen meter calibration
National and industrial safety of experimental equipment
Hydrogen Generator Laboratory Design

《GB/T 32707-2016实验室仪器及设备安全规范 氧弹式热量计》由TC526(全国实验室仪器及设备标准化技术委员会)归口,主管部门为中国机械工业联合会。


Introduction

Core requirements of oxygen bomb calorimeter safety standard

This standard applies to oxygen bomb calorimeters used to measure the calorific value of solid and liquid combustibles such as coal, coke, and petroleum, and specifies the safety technical requirements under working pressure of 2.8MPa~3.2MPa.


Comparison of key safety features

Safety dimension Ordinary oxygen bomb calorimeter Intelligent oxygen bomb calorimeter
Explosion-proof structure Mechanical pressure relief device Electrical pressure monitoring + automatic pressure relief
Electrical protection Basic insulation Double insulation + grounding protection
Data security Manual recording Fault self-diagnosis system

Key data of oxygen bomb pressure test

According to clause 11.4 of the standard, the oxygen bomb needs to pass a 20MPa water pressure test, with the following requirements:

  • Pressure drop within 10 minutes ≤ 0.1MPa
  • Deformation < 0.13mm
  • No reverse leakage from the nozzle

Key technologies for electric shock prevention

Clause 6.3 stipulates the limit of accessible parts:

  • Normal conditions: ≤33V AC/70V DC
  • Fault conditions: ≤55V AC/140V DC
  • Instantaneous discharge: ≤45μC charge

Key points of fire protection design

Clause 9.3 requires the application of flame retardant materials:

  • Shell material FV-1 grade (GB/T 11020)
  • Bottom opening ≤6mm (metal shell)
  • Vertical spacing of baffles ≥25mm

Implementation suggestions

  1. Confirm that the material of the oxygen bomb is 1Cr18Ni9Ti or other pressure-resistant alloy when purchasing
  2. Perform airtightness inspection every month (Appendix A routine test)
  3. Establish a special management system for pressure vessels
  4. Operators must pass special training in GB/T 32707