Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
key technical parameters project td type cbar m type cbar reclosing delay fixed delay reclosing function monitoring cbar automatic reclosing automatic locking function holes一general specifications introductionthis standard industrial sewing machine frames occupational definition
GB/T 32902-2016 in English

GB/T 32902-2016 in English

VALID

Residual current operated circuit-breaker (CBAR) with automatic reclosing function

  • Issued on:2016-08-29
  • Implemented on:2017-03-01
  • File Format:PDF
  • Delivery:Via email within 5 business days
Price(USD): $490.00
$476.00

《GB/T 32902-2016具有自动重合闸功能的剩余电流保护断路器(CBAR)》由TC189(全国低压电器标准化技术委员会)归口,主管部门为中国电器工业协会。


Introduction

Core interpretation of the standard

This standard defines two types of CBARs: integrated type (integrated structure) and assembled type (combination of independent devices), which are further subdivided into two working modes: time-delay type (TD) and monitoring type (M). Key requirements include:

  • Reclosing function is prohibited for circuit breakers with rated residual operating current range of 0.05A-30A and ≤0.03A
  • TD type only allows 1 automatic reclosing, M type up to 3 times and leakage current monitoring
  • The reclosing function must be locked after overload/short circuit action

Comparison of key technical parameters

Project TD type CBAR M type CBAR
Reclosing delay Fixed delay of 20-60 seconds Dynamically adjusted according to IΔar
Monitoring mode No monitoring Voltage≤25V or current≤1mA
Maximum number of actions 1 time 3 times

Safety protection requirements

The standard specifically emphasizes:

  1. Monitoring CBAR must achieve safety monitoring through an isolation transformer or current limiting device
  2. All types must pass 2000m altitude, -5℃~+40℃ environment verification
  3. Electromagnetic compatibility must meet GB/T 17626 series 4 level immunity requirements

Typical application scenarios: Unmanned places such as communication base stations and traffic signal systems need to pass 6kV impulse withstand voltage and alternating damp heat tests.


Test verification system

The standard specifies 11 type test procedures, including:

  • 500 mechanical operation cycles (1/3 with residual current)
  • Ics/Icu short-circuit breaking capacity verification
  • 6-day alternating damp heat test
  • 8kV electrostatic discharge immunity

Conventional tests need to verify the durability of the sign (water/solvent wipe test) and the automatic locking function.

Sample only — not a preview of GB/T 32902-2016