Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
high efficiency air pollution control equipment high-efficiency air pollutant control equipment part technical requirements air pollution prevention test equipment road test methods vacuum flange acoustic design
GB/T 33017.4-2016 in English

GB/T 33017.4-2016 in English

VALID

Technical requirements of high efficiency air pollution control equipment .for assessment一Part4:Electrostatic-fabric integrated precipitator

  • Issued on:2016-10-13
  • Implemented on:2017-05-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $160.00
$156.00
Standard No: GB/T 33017.4-2016
Document status: VALID
Title in English: Technical requirements of high efficiency air pollution control equipment .for assessment一Part4:Electrostatic-fabric integrated precipitator
Title in Chinese: 高效能大气污染物控制装备评价技术要求 第4部分:电袋复合除尘器
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2016-10-13
Implemented on: 2017-05-01
ICS Classification: 13.020.01-Environment and environmental protection in general
Chinese Classification: J88-Environmental protection equipment
Professional Classification: GB-National Standard
Related Keywords: high efficiency air pollution control equipment
high-efficiency air pollutant control equipment part
technical requirements
air pollution prevention
test equipment
Related Topics: Air re-pollution
High-efficiency air pollutant control equipment evaluation technical requirements for air purifiers
atmospheric recombination
Atmospheric Compound Pollutants
Air pollution 4 items
GB/T 33017.4
GB/T 33017.4-2016

《GB/T 33017.4-2016高效能大气污染物控制装备评价技术要求 第4部分:电袋复合除尘器》由TC275(全国环保产业标准化技术委员会)归口,主管部门为国家发展和改革委员会。


Introduction

Interpretation of the evaluation standard for high-efficiency electric bag composite dust collector

GB/T33017.4-2016 "Technical Requirements for Evaluation of High-efficiency Air Pollutant Control Equipment Part 4: Electric Bag Composite Dust Collector" is an important standard in China's environmental field, which aims to guide the performance evaluation and optimization of electric bag composite dust collectors. This article will provide an in-depth interpretation from four aspects: term definition, evaluation indicators, test methods and implementation recommendations.

1. Background of Standard Formulation

Dimensions of Standard Formulation Background Specific Content
Industry Demand With the intensification of industrial pollution, electric bag composite dust collectors are widely used in coal-fired power plants and cement kilns due to their high efficiency.
Technological Evolution From single dust removal to multi-dimensional evaluation that comprehensively considers energy saving, environmental protection and safety, it reflects the progress of dust removal technology.
Policy Promotion The country's emphasis on air pollution prevention and control has promoted the improvement of the relevant standard system.

2. Comparative Analysis of Standard Frameworks

Term Definition and Practical Application

  • High-efficiency Electric Bag Composite Dust Collector:Combines the dual principles of electrostatics and filtration, suitable for complex flue gas environments.
  • Dust concentration in outlet flue gas:Monitored by test equipment to ensure that emissions meet standards. For example, in coal-fired power plants, the dust concentration at the outlet must be ≤15mg/m³ (standard state, dry basis).

3. Implementation suggestions

Steps for enterprises to implement the standard:

  1. Establish a complete quality management system and environmental monitoring system.
  2. Select high-efficiency high-voltage power supply and optimized design of electric bag structure.
  3. Regularly maintain equipment to ensure the long life of key components such as anode plates and filter bags.

Sample only — not a preview of GB/T 33017.4-2016
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend

  • GB/T 33017.1-2016 in English

    GB/T 33017.1-2016 in English

    Technical requirements of high efficiency air pollution control equipment for assessment一Part1:General principle

    2016-10-13
  • GB/T 34607-2017 in English

    GB/T 34607-2017 in English

    Performance assessment of the desulfurization equipment and dust collector for sintering flue gas from iron and steel industry

    2017-10-14