Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
submersible agitator enterprise culture construction norms new jujube plant variety protection system
GB/T 33864-2017 in English

GB/T 33864-2017 in English

VALID

General specification for mass spectrometers

  • Issued on:2017-07-12
  • Implemented on:2018-02-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $160.00
$156.00
Standard No: GB/T 33864-2017
Document status: VALID
Title in English: General specification for mass spectrometers
Title in Chinese: 质谱仪通用规范
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2017-07-12
Implemented on: 2018-02-01
ICS Classification: 71.040.10-Chemical laboratories. Laboratory equipment
Chinese Classification: N60-Laboratory instrument and vacuum instrument in general
Professional Classification: GB-National Standard
Related Topics: mass spectrometer
Tens of millions of mass spectrometers
mass spectrometer main
The mass spectrometer consists mainly of
Various mass spectrometers
Mass spectrometer standard
mass spectrum mass peak
Mass spectrometer resolution
Measure Peak Mass Spectrometer
Mass spectrometer ruler
large mass spectrometer
ion trap mass spectrometer
Other mass spectrometers
icp mass spectrometer
Used mass spectrometer
icp mass spectrometer
Domestic mass spectrometer
The quality of the spectrometer
The quality of the spectrometer
Essence Spectrum
trap mass spectrometer
High quality icp spectrometer
mass spectrometry hplc
Mass spectrometer sample preparation
Essence Spectrum
Pole for mass spectrometer and mass spectrometer
Domestic small mass spectrometer
Premium spectrometer
d spectrometer
Appearance
Spectrometer Premium
Various mass spectrometers
Mass Spectrometry
Various mass spectrometers
automated mass spectrometer
Mass Spec Specifications
What gas source does the mass spectrometer use?
Premium spectrometer
Mass spectrometer domestic
m7 mass spectrometer
surface mass spectrometer
Dongyi spectrometer
mass spectrometer
Beijing General Instrument
mass spectrometer ion ratio mass spectrometer
Combined mass spectrometer
Mass Spectrometer Degassing
Ordinary mass spectrometer
mass spectrometer
General mass spectrometer
Other mass spectrometers
Mass spectrometer
Spectrum material
Mass peak measurement
Mass flow analyzer
Mass spectrometer operation
Mass Spec Specifications
How many mass spectrometers
polarograph, voltammeter
mass spectrometer water
Mass Spectrometer Specifications
The earliest mass spectrometers
A Spectrum Instrument
mass spectrometer mass spectrometer
Mass Spectrometer Components
multispectral instrument
Polarograph/Voltammeter
mass spectrometer now
spectrometer spectrum
Series Mass Spectrometer
dual energy spectrometer
Zhe spectrum instrument
multistage mass spectrometer
Spectrum Analyzer
Component mass spectrometer
pair spectrum instrument
Yipushi
Frontiers in Mass Spectrometry
mass spectrometer substrate
Frontiers in Mass Spectrometry
Hydrogen mass spectrometer
How to use the mass spectrometer
Water quality spectrometer
Spectrum Analyzer
Spectrum Association Instrument
Water quality spectrometer
Mass spectrometer
Mass spectrometer in mass spectrometry
Mass Spectrometer Terminology
Nitrogen blowing instrument mass spectrometer
Secondary Rod Mass Spectrometer
high frequency mass spectrometer
old fashioned mass spectrometer
spectrometer water quality
which mass spectrometer
Water quality meter and spectrometer
The mass spectrometer initially
Mass spectrometer feed
Sample of mass spectrometer
mass spectrometer military
Spectrum Profiler
How to use a mass spectrometer
mass spectrometer femtosecond
The mass spectrometer has been used for 5 years
mass spectrometer and general
floor standing mass spectrometer
Mass spectrometer sample water
Peak + Mass Spectrometer
early mass spectrometer
Mass Spectrometer Oxygen Content
Spectrometer complete machine
Gas source for mass spectrometer
Spectroscopy and spectrometers
mass spectrometer
Used mass spectrometer
Mass Spectrometer Nitrogen Oxygen
Adsorber mass spectrometry
Zai Yi Pu
Three-spectrum instrument
Spectrometer
Voltammeter Polarograph
mass spectrometer
mass spectrum+m/
Tank Spectrum
Instrument Spectrum
Instrument Broad Spectrum
new mass spectrometer
Mass spectrometers and mass spectrometers
Gas source for mass spectrometer
range of mass spectrometry
mass spectrometer large
. Mass spectrometer
Aluminum target for mass spectrometer
Mass spectrometer specific
Mass spectrometer based on
Mass Spectrometer Nitrogen Content
Ion Trap Mass Spectrometers and Mass Spectrometers
Purity for mass spectrometry
Spectrum
Xianyi Spectrum
Military mass spectrometer
Quadruple mass spectrometer
Mass spectrometer analyzer
Yitong
Secondary mass spectrometer
Ion trap mass spectrometer
Nitrogen mass spectrometer
Mass spectrometers and mass spectrometers
spectrometer water quality
Centenary of mass spectrometer
conventional mass spectrometry
icp mass spectrometer
Trap Mode Mass Spectrometer
chemical mass spectrometer
Spectrometer
Mass Spectrometer Nitrogen
How to use a high-quality spectrometer
Mass spectrometer series
Yi San Spectrum
mass spectrometer
"Mass spectrometer
Mass spectrometer use
mass spectrometer substance
Applications of Spectrum
small mass spectrometer
mass spectrometer and icp mass spectrometer
spectrum instrument spectrum
Solid state mass spectrometer
Current mass spectrometer
Spectrometer and energy spectrometer
Mass spectrometer use
mass spectrometry imaging mass spectrometry
Non-target mass spectrometer
Military mass spectrometer
GB/T 33864
GBT33864
GB/T 33864-2017
Components of a mass spectrometer
How to use a mass spectrometer
Mass Spectrometer Composition
Carbon 14 mass spectrometer
accelerator mass spectrometer
mass spectrometer carbon
Accelerated mass spectrometer structure
Gloria Spectrometer
edax energy spectrometer
icp-mas mass spectrometer
NORAN energy spectrometer
Spectrometer mass spectrometry instrument parameters
Mass spectrometer hazards
Desorption Mass Spectrometer Hydrogen
Mass spectrometer research
Mass spectrometer FID module
APIMS mass spectrometer
Niton xL3t500 spectrometer
Mass spectrometer manufacturing
Mass spectrometer acceptance
Specifications for using quality inspection equipment
Mass spectrometer production
Use of texture analyzer
Iron spectrometer
process mass spectrometer
Mass spectrometer weekly quality control
Mass spectrometer manufacturer

《GB/T 33864-2017质谱仪通用规范》由TC124(全国工业过程测量控制和自动化标准化技术委员会)归口,TC124SC6(全国工业过程测量控制和自动化标准化技术委员会分析仪器分会)执行,主管部门为中国机械工业联合会。


Introduction

GB/T 33864—2017 General Specification for Mass Spectrometer: In-depth Interpretation

Background of Standard Formulation and Analysis of Technology Evolution

As an important tool for qualitative and quantitative analysis of substances, mass spectrometer plays an irreplaceable role in scientific research and industrial applications. The formulation of GB/T 33864—2017 General Specification for Mass Spectrometer aims to unify the technical requirements, test methods and inspection rules of mass spectrometers to ensure the consistency of product quality and performance.

With the development of mass spectrometry technology, the application scenarios of mass spectrometers are constantly expanding. From laboratory analysis to industrial process control, to mobile detection, the demand for mass spectrometers is showing a diversified trend. This standard fully considers the technical requirements in different usage environments and reflects the importance of standardization work.

Comparison of mass spectrometer classification and standard framework

Classification dimension Laboratory mass spectrometer Process mass spectrometer Mobile mass spectrometer
Mass accuracy ±0.2u ±0.3u ±0.3u
Mass stability ±0.2u/8h ±0.3u/24h ±0.3u/4h
Applicable environment Laboratory environment, strict temperature and humidity control Fixed on-site monitoring Mobile detection, adapt to complex environments

Mass spectrometer performance requirements and test method interpretation

According to GB/T 33864-2017, the performance requirements of mass spectrometers include key indicators such as mass range, mass accuracy, and mass stability. The following are specific requirements:

Case study: practical application of mass spectrometer detection limit

Taking a laboratory mass spectrometer as an example, when the signal-to-noise ratio is not less than 3:1, the detection limit should meet the minimum value requirement. Through actual test data (as shown in the figure), verify whether its performance indicators meet the standards.

Implementation Recommendations and Precautions

  • Purchase Recommendations:Choose the appropriate type of mass spectrometer (laboratory/process/mobile) according to the application scenario. Focus on core indicators such as mass accuracy and stability.
  • Installation and Maintenance:Installation and commissioning must be carried out in strict accordance with standard requirements, and the equipment must be calibrated and maintained regularly to ensure long-term stable operation.
  • Safety Precautions:Pay special attention to safety requirements such as protective grounding and dielectric strength to ensure the safety of the instrument during use.

Sample only — not a preview of GB/T 33864-2017
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.