Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
energy storage battery electrochemical energy storage station station electrochemical energy storage station electrochemical energy storage station chinastandards.net battery management system x-ray pipeline crawler common name quizalofop-p-ethyl high-pressure plastic parts
GB/T 34131-2017 in English

GB/T 34131-2017 in English

SUPERSEDED

Technical standard for battery management system of electrochemical energy storage station

  • Issued on:2017-07-31
  • Implemented on:2018-02-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $130.00
$127.00
Standard No: GB/T 34131-2017
Document status: SUPERSEDED
Superseded by: GB/T 34131-2023 Battery management system for electrical energy storage
Superseded on: 2023-10-01
Title in English: Technical standard for battery management system of electrochemical energy storage station
Title in Chinese: 电化学储能电站用锂离子电池管理系统技术规范
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2017-07-31
Implemented on: 2018-02-01
ICS Classification: 27.180-Wind turbine systems and other alternative sources of energy
Professional Classification: GB-National Standard
Related Keywords: energy storage battery
electrochemical energy storage station station
electrochemical energy storage station
electrochemical energy storage station chinastandards.net
battery management system
Related Topics: electrochemical
power station
Lithium Ion Battery
Electrochemical battery
Electrochemical standard
chemical ion source
Discharge + battery voltage
battery discharge voltage
chemical ion source
battery battery voltage
battery discharge voltage
discharge battery voltage
Battery Electrochemical Spectroscopy
battery in electrochemical
atom+lithium+ ionization
battery management
ionic half cell
Negative Chemical Ion Source vs. Positive Chemical Ion
Lithium-ion battery electrochemical window
Electrochemical Measurement Technology
battery power
Energy storage power station
Energy storage power station
electron ionization
thermal management battery
electron ionization
battery electrochemistry
Lithium Electrochemistry
al-ion battery
Electrochemical standard
battery management
electrochemical energy storage
high energy ion tube
high energy ion tube
non-traditional lithium battery technology
battery chemistry
Electrochemistry of Half Cells
battery electrochemical window
ionization system
"Electrochemistry
Electrochemical energy storage power station
GBT34131
GBT 34131-2017
electrochemical energy storage
Formation test of university lithium battery cells
Lithium-ion battery discharge curve
Single cell lithium battery charging management
Lithium-ion battery energy storage cabin technology
Application areas of lithium-ion batteries
T/CES 169-2022 "Technical Specifications for Commissioning of Lithium-Ion Battery Energy Storage Power Stations"
nb/t 42091-2016 Lithium-ion battery technology for electrochemical energy storage power stations
Full text of technical specifications for lithium-ion battery energy storage compartments
Lithium-ion battery energy storage power station debugging technology
Electrochemical Battery Management System
Portable lithium-ion battery energy storage power technology
Lithium-ion energy storage battery pack and system safety
Electrochemical energy storage device supervision
Dual-ion battery common technology
Lithium battery substation
Lithium-ion battery silicon
gb/t 34131-2023
gbt34131
gbt34131-2023
gbt 34131-2022
gb/t 34131-2017

《GB/T 34131-2017电化学储能电站用锂离子电池管理系统技术规范》由524(中国电力企业联合会)归口,主管部门为中国电力企业联合会。


ChinaStandards.net is in charge of this English translation. In case of any doubt about the English translation, the Chinese original shall be considered authoritative.

This standard is developed in accordance with the rules given in GB/T 1.1-2009.

This standard was proposed by China Electricity Council.

This standard is under the jurisdiction of National Technical Committee on Electric Energy Storage of Standardization Administration of China (SAC/TC 550).


Technical standard for battery management system of electrochemical energy storage station

1 Scope

This standard specifies the service conditions, functional requirements, inspection and test items, etc. of lithium-ion battery management system for electrochemical energy storage station.

This standard is applicable to the constructed, renovated and extended electrochemical energy storage stations.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

GB/T 191 Packaging - Pictorial marking for handling of goods
GB/T 2423.4 Environmental testing for electric and electronic products - Part 2: Test method - Test Db: Damp heat, cyclic (12h+12h cycle)
GB/T 16935.1 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
GB/T 17626.2 Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test
GB/T 17626.4 Electromagnetic compatibility - Testing and measurement techniques - Electrical fast transient/burst immunity test
GB/T 17626.5 Electromagnetic compatibility - Testing and measurement techniques - Surge immunity test
GB/T 17626.8 Electromagnetic compatibility - Testing and measurement techniques - Power frequency magnetic field immunity test
GB/T 17626.12 Electromagnetic compatibility - Testing and measurement techniques - Ring wave immunity test

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply.

3.1
electrochemical energy storage station
station with the electrochemical battery as an energy storage element, and capable of power storage, conversion and discharge

3.2
power conversion system; PCS
system realizing bidirectional energy conversion between energy storage battery and AC network

3.3
cell
electrochemical device consisting of electrodes and electrolytes that form the minimum unit of a battery pack module and capable of storing the obtained electric energy in the form of chemical energy and converting the chemical energy into electric energy

3.4
battery module
unit consisting of two or more cells connected electrically

3.5
battery management unit; BMU
unit managing a battery module, monitoring battery state (voltage, temperature, etc.) and providing communication interface for the battery

3.6
battery management system; BMS
system monitoring the battery state (temperature, voltage, current, state of charge, etc.) and providing communication interface and protection for the battery

3.7
state of energy; SOE
ratio of the actual (remaining) dischargeable capacity (Wh) to the rated capacity (Wh) of the battery

3.8
battery-balancing
energy balancing state between different batteries maintained by taking energy transfer measures to reduce the capacity and voltage differences between the batteries

4 Service conditions

4.1 Ambient temperature

The ambient temperature during equipment operation shall not be higher than 45℃ while not be lower than 0℃.

4.2 Relative humidity

The daily and monthly average relative humidity shall not be greater than 95% and 90% respectively. No condensation shall occur on the equipment.

4.3 Altitude

<2,000m.

5 Functional requirements

5.1 Basic requirements

5.1.1 The topology configuration of BMS shall be matched and coordinated with the topology and battery grouping mode of PCS, and the operation state of batteries shall be optimally controlled and comprehensively managed.

5.1.2 The specific implementation level of each function in the BMS functional requirements is determined by the topology configuration of BMS and should be implemented in layers locally.

5.2 Measurement requirements

BMS shall be able to measure the relevant electrical and thermal data of the battery in real time, including parameters such as cell voltage, battery module temperature, battery module voltage, series circuit current, insulation resistance, etc. The measurement precision of each state parameter shall meet the following requirements:

a) the current sampling resolution should be determined in combination with battery capacity and charging/discharging current; the measurement error shall not be greater than ±0.2%, and the sampling period shall not be greater than 50ms;

b) the measurement error of cell voltage shall not be greater than ±0.3%; the sampling period shall not be greater than 200ms;

c) the temperature sampling resolution shall not be greater than 1℃, the measurement error shall not be greater than ±2℃, and the sampling period shall not be greater than 5s.

5.3 Calculation requirements

BMS shall be able to estimate the state parameters such as state of charge, charging/discharging electric energy (Wh) and maximum charging/discharging current, and provided with functions such as power failure protection and uploading to monitoring system. The estimation precision of each state parameter shall meet the following requirements:

a) the estimation precision of SOE shall not be greater than 8%, and the calculation update period shall not be greater than 3s; SOE should be provided with a self-calibration function.

b) the calculation error of electric energy shall not be greater than 3%.

5.4 State parameter information uploading function

BMS shall be provided with internal information collection and interaction functions, and able to upload the information of cell and battery to the monitoring system and PCS.

5.5 Fault diagnosis function

BMS shall be able to monitor the operation state of the battery, diagnose the abnormal operation state of the battery or BMS itself, and send relevant alarm signals to the monitoring system and PCS.

5.6 Electrical protection function of battery

BMS shall be provided with electrical protection functions of battery such as over-voltage protection, under-voltage protection, over-current protection, short-circuit protection, over-temperature protection and leakage protection, and able to send alarm signals or trip commands to implement local fault isolation.

Foreword i
1 Scope
2 Normative references
3 Terms and definitions
4 Service conditions
5 Functional requirements
6 Inspection and test items
7 Marking and packaging

Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend