Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
magnetic flux leakage magnetic flux leakage detector nondestructive testing thickness ≤20mm steel wire ropes/cables wall thickness ≤20mm steel plates core test requirements secondary-ion mass spectrometry sputter depth locking torque
GB/T 34370.9-2020 in English

GB/T 34370.9-2020 in English

VALID

Nondestructive testing of amusement equipments—Part 9:Magnetic flux leakage testing

  • Issued on:2020-11-19
  • Implemented on:2021-06-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $250.00
$243.00
Standard No: GB/T 34370.9-2020
Document status: VALID
Title in English: Nondestructive testing of amusement equipments—Part 9:Magnetic flux leakage testing
Title in Chinese: 游乐设施无损检测 第9部分:漏磁检测
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2020-11-19
Implemented on: 2021-06-01
ICS Classification: 97.200.40-Playgrounds
Chinese Classification: Y57-Toys
Professional Classification: GB-National Standard
Related Keywords: magnetic flux leakage
magnetic flux leakage detector
nondestructive testing
thickness ≤20mm steel wire ropes/cables
wall thickness ≤20mm steel plates
Related Topics: Non-destructive testing
Non-destructive testing standards
Flux leakage
Non-destructive testing Flux leakage testing
Magnetic flux leakage detection
Flux Leakage Nondestructive Testing
Magnetic flux leakage detector for non-destructive testing
Test English
lossless flux leakage and
Lossless Flux Leakage
9 items of water quality testing
Nondestructive Testing Terminology Flux Leakage Testing
rides
Nondestructive Testing Terminology Flux Leakage Testing
rides
magnetizer
Testing equipment
Detect device power
Performance leak detection equipment
Test version
Missing detection
leak
Water testing 9 items
Antibody Upstream Detection
Flux leakage sensor
amusement
gb detection
Flux leakage instrument
How to detect magnetic flux leakage
Magnetic flux leakage detection level two
Leakage detection
Leakage detection
Magnetic detection
GB/T 34370.9
GB/T 34370.9-2020
Non-destructive testing
detection
Corner leak test
Leaky cable detection
Amusement equipment production inspection standards
Magnetizer detection
High pressure leakage detection
Pipeline magnetic flux leakage testing national standard
Magnetic flux leakage testing standards

《GB/T 34370.9-2020游乐设施无损检测 第9部分:漏磁检测》由TC250(全国索道与游乐设施标准化技术委员会)归口,主管部门为国家标准化管理委员会。


Introduction

Interpretation of the core content of the standard

This standard specifies the application specifications of the magnetic flux leakage detector in the ferromagnetic components of amusement facilities, focusing on:

  • Steel pipes with an outer diameter ≥38mm and a wall thickness ≤20mm
  • Steel plates with a thickness ≤20mm
  • Steel wire ropes/cables with a diameter ≥6mm

Analysis of key technical points

Detection objects Sensitivity requirements Typical defects
Steel pipes/plates Can detect 20% wall thickness defects Corrosion pits, mechanical damage, cracks
Wire rope Detect 1 broken wire or 1% cross-sectional area loss Broken wire, metal cross-sectional area loss

Key requirements of the detection system

Equipment composition

The complete detection system should include:

  1. Magnetization unit (magnetization intensity ≥30kA/m)
  2. Hall sensor array (resolution ≤0.5mm)
  3. Signal processing system (sampling rate ≥100kHz)

Calibration specifications

Three types of standard test pieces are required:

  • Calibration specimen: containing 20%-80% wall thickness step groove
  • Comparison specimen: with spherical artificial defects
  • On-site verification specimen: the same material as the inspected piece

Implementation suggestions

Detection process design

It is recommended to adopt the orthogonal scanning strategy:

  • Axial + circumferential dual-channel detection
  • Scanning speed ≤0.5m/s (manual) or ≤3m/s (automatic)
  • Coverage ≥110% (including 10% overlap)

Defect assessment process

  1. Preliminary screening: signal threshold alarm
  2. Verification: 90° direction rescan
  3. Quantitative: ultrasonic/radio-assisted measurement

Analysis of Standard Evolution

Main improvements compared with the previous version of the standard:

  • Added technical requirements for wire rope testing
  • Specified the dual modes of LMA (metal loss assessment) and LF (magnetic flux leakage testing)
  • Refined the manufacturing tolerance of the comparison specimen (±0.2mm)