Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
rail transit driver controller rail transit driver controller keywords driver controller locomotive driver controller master controller introduction gb/t six-knife cardiac dissection longding root puncture
GB/T 34573-2017 in English

GB/T 34573-2017 in English

VALID

Railway applications - Master controller

  • Issued on:2017-09-29
  • Implemented on:2018-04-01
  • File Format:PDF
  • Delivery:Within 1 day
Price(USD): $112.00
$109.00
Standard No: GB/T 34573-2017
Document status: VALID
Title in English: Railway applications - Master controller
Title in Chinese: 轨道交通 司机控制器
Language: English
File Format: Electronic (PDF)
Delivery: Within 1 day
Issued on: 2017-09-29
Implemented on: 2018-04-01
ICS Classification: 29.280-Electric traction equipment
Professional Classification: GB-National Standard
Related Keywords: rail transit driver controller
rail transit driver controller keywords
driver controller
locomotive driver controller
master controller introduction gb/t
Related Topics: driver
judiciary
GB/T 34573
GB/T+34573
Ministry of Communications
majority justice
track ball machine
track control equipment
Gu Si
gbt 34573
gb+t+34573
channel controller
GBT34573
GB/T 34573-2017
Textiles for Rail Transit
driver controller
Special transformer technology for rail transit
Networks in rail transit
Rail transit industry data
gb34573

《GB/T 34573-2017轨道交通 司机控制器》由TC278(全国轨道交通电气设备与系统标准化技术委员会)归口,TC278SC1(全国轨道交通电气设备与系统标准化技术委员会机车车辆电气分会)执行,主管部门为国家铁路局。


Introduction

GB/T 34573—2017 Interpretation of the Standard for Rail Transit Driver Controller

Keywords:Rail Transit, Driver Controller, Technical Requirements, Inspection Rules

1. Background and Significance of the Standard

GB/T 34573—2017 "Rail Transit Driver Controller" was proposed by the National Railway Administration to standardize the technical requirements and inspection methods for driver controllers for locomotives and rolling stock. This standard combines the development trends of rail transit technology at home and abroad to ensure the reliability and safety of equipment in complex environments.


2. Comparison of standard frameworks

Dimensions GB/T 34573—2017 Comparison with international standards Scope of application
Technical requirements Detailedly specifies the rated parameters, mechanical properties and electrical properties of the driver controller. Aligned with the IEC 60077 series of standards and compatible with international specifications. Applicable to driver controllers for locomotives and vehicles.
Test methods Including temperature rise test, insulation performance test and electromagnetic compatibility assessment. Meet the requirements of GB/T 24338.4 rail transit electromagnetic compatibility standard. Ensure product quality consistency.

3. Analysis of core technical requirements

Mechanical properties: The operating torque range of the handle is 0.4~8.5 N·m, and the impact and vibration performance meets the requirements of Class 1 B in GB/T21563-2008.

Electrical properties: The comparative tracking index (CTI value) of the insulating material should not be less than 175 V. The power frequency withstand voltage test voltage value is different according to the rated insulation voltage U, and can reach up to 1500 V.

Fire prevention and environmental protection requirements: It is stipulated that low-smoke, halogen-free, non-toxic and flame-retardant materials should be used, and environmentally friendly devices and lead-free soldering processes are recommended.

4. Implementation Recommendations

Case Analysis: Compliance Improvement of a Locomotive Driver Controller

In actual applications, it is recommended that manufacturers strictly follow the standards for design and production:

  • Select insulating materials that meet the CTI value requirements;
  • Optimize the handle operating torque to improve user experience;
  • Ensure that all components pass the temperature rise and insulation performance tests.

Sample only — not a preview of GB/T 34573-2017
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.