Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
overall energy-saving evaluation overall energy-saving performance evaluation method building envelopes civil building envelopes household gas burning appliances static load meter conductive charge
GB/T 34606-2017 in English

GB/T 34606-2017 in English

VALID

Evaluation method of overall energy-saving performance of building envelope

  • Issued on:2017-10-14
  • Implemented on:2018-05-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $250.00
$243.00

《GB/T 34606-2017建筑围护结构整体节能性能评价方法》由TC452(全国建筑节能标准化技术委员会)归口,主管部门为住房和城乡建设部。


Introduction

Interpretation of the National Standard of the People's Republic of China GB/T 34606-2017

I. Overview of the Standard

GB/T 34606-2017 mainly stipulates the evaluation method of the overall energy-saving performance of building envelopes, and is applicable to the overall energy-saving evaluation of civil building envelopes. The standard covers the definition of terms, individual performance indicators, weight distribution and scoring system.

II. Analysis of Core Content

Item Description Weight
Heat Transfer Coefficient (Q1) Measures the heat transfer efficiency of the envelope structure, using the average value calculation method. 0.45
Thermal insulation performance (Q2) Thermal insulation effect of the envelope structure is evaluated through the temperature difference Δt. 0.05
Structural thermal bridge (Q3) Reflects the impact of heat flow-intensive parts in the building structure on energy consumption. 0.10

III. Scoring system for individual performance

Example of scoring for heat transfer coefficient

Zc value range Score
Zc ≤ 0.30 100
0.40 < Zc ≤ 0.50 80

IV. Implementation suggestions

In actual applications, it is recommended to give priority to the test report data and conduct on-site evaluation in combination with the thermal defect detector. The setting of reference buildings should strictly follow the standard requirements to ensure the accuracy of comparative analysis.


V. Significance and Challenges

This standard provides a scientific basis and evaluation method for building energy conservation, which helps to reduce energy consumption. However, in practical applications, attention should be paid to the accuracy of test data and the selection of reference buildings.