GB/T 35451.2-2018 in English
VALIDPolypropylene(PP)structure-wall piping systems for underground drainage and sewerage—Part 2:Polypropylene spirally enwound structure-wall pipes
- Issued on:2018-12-28
- Implemented on:2019-07-01
- File Format:PDF
- Delivery:Within 1 day
$334.00
《GB/T 35451.2-2018埋地排水排污用聚丙烯(PP)结构壁管道系统 第2部分:聚丙烯缠绕结构壁管材》由TC48(全国塑料制品标准化技术委员会)归口,TC48SC3(全国塑料制品标准化技术委员会塑料管材、管件及阀门分会)执行,主管部门为中国轻工业联合会。
Introduction
Analysis of the core content of the standard
| Technical dimensions | Type A structural wall tube | Type B structural wall tube |
|---|---|---|
| Structural characteristics | Continuous threaded rib cavity structure between inner and outer walls | Smooth inner wall + outer wall spiral ribs |
| Minimum wall thickness (mm) | e5,min≥1.1(DN200) | e4,min≥1.5(DN200) |
| Applicable temperature | Long-term use temperature ≤45℃ | |
Key technical requirements of materials
Polypropylene resin must meet the following requirements:
- PP-B copolymer resin content ≥95%
- Density 895-920kg/m³
- Oxidation induction time ≥20min(200℃)
- MFR grade control (AD grade)
Typical case: When DN800 pipe uses MFR B grade raw material, its welding compatibility is better than that of C grade material.
Mechanical properties
| Test items | SN4 grade requirements | Test method |
|---|---|---|
| Ring stiffness | ≥4kN/m² | GB/T 9647 |
| Impact performance | TIR≤10% | GB/T 14152 |
| Creep ratio | ≤4% | GB/T 18042 |
System sealing test
Three sealing verification methods:
- Low pressure hydrostatic test: 0.005MPa pressure maintenance for 15min
- High pressure hydrostatic test: 0.05MPa pressure maintenance for 15min
- Negative pressure test: -0.03MPa vacuum degree detection
Engineering application tips:For DN≥600mm pipes, it is recommended to use condition C test (with additional 1° angle deviation).
Suggestions for the implementation of the standard
1. Selection basis: Select the ring stiffness grade according to the burial depth load. SN4 is suitable for 3-6m burial depth
2. Construction points:
- MFR difference of welding material ≤1 level
- Socket and spigot matching length ≥85mm
- Ice crystal symbol should be marked during winter construction
3. Acceptance criteria: Reverse bending shall not occur when the deformation of the ring flexibility test is 30%

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 44574-2024 in English
Plastic check valves for anti-pollution for discharge piping systems inside buildings
2024-09-29 -

GB/T 33608-2017 in English
Unplasticized poly(vinyl chloride)(PVC-U)structured-wall pipes for soil and waste discharge inside buildings
2017-05-12 -

GB/T 13021-2023 in English
Polyolefin pipes and fittings—Determination of carbon black content—Test method of alcination and pyrolysis
2023-08-06 -

GB/T 5836.1-2018 in English
Unplasticized poly(vinyl chloride)(PVC-U)pipes for soil and waste discharge inside buildings
2018-12-28 -

GB/T 8801-2007 in English
Test method for unplasticized polyvinyl chloride(PVC-U)fittings by falling
2007-12-05 -

GB/T 13526-2007 in English
Unplasticized polyvinyl chloride(PVC-U) pipes—Dichloromethane resistance test method
1992-06-23 -

GB/T 24452-2009 in English
Plastics piping systems for soil and waste discharge (low and high temperature) inside buildings—Chlorinated poly (vinyl chloride)(PVC-C)
2009-10-15 -

GB/T 37842-2019 in English
Ball valves of thermoplastics materials
2019-08-30