Introduction
1. Background and significance of the standard
GB/T 35862-2018 "Determination of residual volatile organic compounds in surfactants - Headspace gas chromatography-mass spectrometry (GC-MS) method" is an important national standard used to regulate the detection method of residual volatile organic compounds (VOCs) in surfactants. With the enhancement of environmental awareness and the improvement of product quality requirements, the formulation of this standard provides a scientific and unified technical basis for the industry.
2. Comparison of standard frameworks
| Chapter Contents | GB/T 35862-2018 | Comparison with international standards | Differences in industry standards |
|---|---|---|---|
| Scope and Applicability | Applicable to the determination of VOC residues in various surfactants | In line with international standards such as ISO 16000 series | Meet domestic industry needs and have independent characteristics |
| Detection Principle | Headspace Gas Chromatography-Mass Spectrometry (GC-MS) | International General Method | Consistent with EU and US standards |
| Key parameters | Headspace temperature: 80±1℃, equilibration time 40 minutes | International standard recommended range 30-60 minutes | Domestic standards are more operational |
3. Standard implementation recommendations
3.1 Laboratory conditions requirements
Hardware facilities:Equipped with headspace gas chromatography-mass spectrometry (GC-MS), headspace injector and other equipment to ensure that the laboratory environment meets the temperature and humidity control requirements.
Staff capabilities:Testers must undergo professional training and be familiar with GC-MS operating procedures and data processing methods.
3.2 Sample preparation and processing
In practical applications, it is recommended to weigh samples strictly in accordance with standard requirements and ensure that the headspace bottle is well sealed. For samples with higher volatility, the sampling volume can be appropriately reduced to avoid detection errors.
3.3 Data analysis and quality control
When establishing a standard curve, it is necessary to ensure that the linear relationship between each concentration point is good (the correlation coefficient should be greater than 0.99). For precision requirements, the relative deviation of two measurement results by the same operator should be less than 10%.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 7463-2008 in English
Surface active agents - Determination of the power to dispersecalcium soap - Acidimetric method (modifled Schoenfeldt method)
2008-05-28 -

GB 7382-1987 in English
Surface active agents--Determination of the power to disperse calcium soap--Acidimetric method (Modified Schonfeldt method)
- -

GB/T 9291-2008 in English
Surface active agents - Method of testing of the restraining effect of levelling agents for disperse dyes on dyeing polyester textile under high temperature conditions
2008-05-14