Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
smart substation devices smart substation smart substation introduction national standard smart substations standard overview digital interface effective exploration activities personal dose equivalents sizing mill
GB/T 36273-2018 in English

GB/T 36273-2018 in English

VALID

Digital interface technical specification for relaying protection and security automatic equipment in smart substation

  • Issued on:2018-06-07
  • Implemented on:2019-01-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $220.00
$214.00
Standard No: GB/T 36273-2018
Document status: VALID
Title in English: Digital interface technical specification for relaying protection and security automatic equipment in smart substation
Title in Chinese: 智能变电站继电保护和安全自动装置数字化接口技术规范
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2018-06-07
Implemented on: 2019-01-01
ICS Classification: 29.240-Power transmission and distribution networks
Professional Classification: GB-National Standard
Related Keywords: smart substation devices
smart substation
smart substation introduction national standard
smart substations standard overview
digital interface
Related Topics: relay protection
Smart substation
GBT36273
GB/T 36273-2018
Code for design of relay protection and safety automatic devices
Communication interface device for relay protection
GB/T14285-2006 Technical regulations for relay protection and safety automatic devices
Smart substation measurement device control technology
Substation relay protection grounding technology

《GB/T 36273-2018智能变电站继电保护和安全自动装置数字化接口技术规范》由524(中国电力企业联合会)归口,主管部门为中国电力企业联合会。


Introduction

National Standard of the People's Republic of China GB/T 36273—2018

Technical Specification for Digital Interface of Relay Protection and Safety Automatic Devices in Smart Substations

Standard Overview and Background

This standard is proposed and managed by the China Electricity Council and is applicable to smart substations with a voltage level of $110~\mathrm{kV}(66~\mathrm{kV})$ and above. The purpose of the standard is to standardize the digital interface of relay protection and safety automatic devices and to improve the reliability, selectivity, sensitivity and speed of the relay protection system.

Core content framework

Chapter Main content Scope of application
Virtual terminal interface specification Defines the modeling and configuration requirements of GOOSE and SV virtual terminals to ensure the accuracy and consistency of information interaction. Smart substation devices of all voltage levels.
Physical interface specification Specifies the requirements for optical fiber types, wavelengths and connectors to ensure the stability and reliability of data transmission. Communication interface between process layer devices.
Press plate configuration Specifies the functions and configuration methods of soft and hard press plates, emphasizing the need for remote operation control. Device operation status management and control.

Explanation of professional terms

Application case of GOOSE mechanism

GOOSE (Generic Object Oriented Substation Events) is an event message mechanism for substation communication. For example, in a smart substation, the position status information of circuit breakers and switches is usually transmitted through dual-point information, while ordinary telesignaling signals are transmitted through single-point information. This method ensures the real-time and reliability of information interaction.

Technology Evolution Analysis

Compared with traditional substations, smart substations achieve efficient communication between relay protection devices and process layer equipment through digital interfaces. This technological evolution not only improves the intelligence level of the system, but also reduces the complexity of the secondary circuit, providing greater convenience for operation, maintenance and management.

Implementation Suggestions

  • During the engineering design phase, strictly select the optical fiber type and wavelength in accordance with the standard requirements to ensure communication quality.
  • When configuring virtual terminals, it is recommended to use Chinese descriptions to improve readability and ensure the consistency of the desc and dU attributes in the ICD file.
  • In actual operation, regularly check the communication status and CRC check code of the device to promptly detect and handle abnormal situations.

Sample only — not a preview of GB/T 36273-2018
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend

  • GB/T 24842-2018 in English

    GB/T 24842-2018 in English

    Overvoltage and insulation coordination of 1 000 kV UHV AC transmission project

    2018-07-13
  • GB/T 40864-2021 in English

    GB/T 40864-2021 in English

    Technical requirements for relaying protection of flexible alternating current transmission equipment connecting to the system