GB/T 36992-2019 in English
VALIDManual interdental brushes
- Issued on:2019-06-04
- Implemented on:2020-01-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$243.00
| Standard No: | GB/T 36992-2019 |
| Document status: | VALID |
| Title in English: | Manual interdental brushes |
| Title in Chinese: | 手动牙间刷 |
| Language: | English |
| File Format: | Electronic (PDF) |
| Delivery: | Via email within 1~3 business days |
| Issued on: | 2019-06-04 |
| Implemented on: | 2020-01-01 |
| ICS Classification: | 11.060.20-Dental equipment |
| Chinese Classification: | Y89-Other daily necessaries |
| Professional Classification: | GB-National Standard |
| Related Keywords: | manual interdental brushes
manual interdental brushes introduction interpretation main stem salt main stem 1.9-2.3mm specification main body |
| Related Topics: | toothbrush
animal teeth Special toothbrush About electric toothbrushes GBT36992 GB/T 36992-2019 brush denture toothbrush tooth Manual adult toothbrush execution gb 36992 |
《GB/T 36992-2019手动牙间刷》由TC492(全国口腔护理用品标准化技术委员会)归口,TC492SC2(全国口腔护理用品标准化技术委员会牙刷分会)执行,主管部门为中国轻工业联合会。
Introduction
Interpretation of the core content of the standard
This standard revision adopts the ISO16409:2006 international standard, which mainly regulates the terminology, classification system and quality requirements of manual interdental brushes. Compared with the ISO original version, new key technical indicators such as main stem fastness ≥15N and heat resistance are added. For details of the structural adjustment, please refer to Appendix A.
Comparison of key technical requirements
| Indicator | GB/T36992-2019 | ISO16409:2006 | Difference description |
|---|---|---|---|
| Specification classification | Grade 7 (0.6-2.3mm) | Grade 6 | New 1.9-2.3mm specification |
| Main body strength | ≥15N | Not specified | Specific to China |
| Fatigue resistance test | 500g/30 times/min | 400g/25 times/min | Strictness increased by 25% |
Product classification system
First category replaceable brush head: Suitable for professional dental clinics, such as Double Clean medical-grade products, the brush head replacement cycle is recommended to be ≤3 months
Second category integrated structure: Mainstream for mass consumption, typical representatives such as Weimezi daily care series
Third category handleless design: Used in special tooth cleaning scenarios, requires a special gripper
Key points of the test method
1. Aperture test: Use a hardened steel measuring plate with a tolerance of ±0.02mm, and require that the main stem does not deform when the brush head passes through the minimum aperture
2. Filament fastness test: Select a hole 0.2mm larger than the passing aperture and perform 80 reciprocating friction tests
3. Fatigue test: 45° swing test under 500g counterweight, and the main stem has no breakage after 20 cycles
Implementation suggestions
Manufacturers: It is recommended to establish a metal main stem salt spray test process to prevent rust problems; the packaging label must include the specification model (such as IS-3 for 1.1-1.2mm)
Medical institutions: Select the specification according to the size of the patient's tooth gap, 0.6-1.0mm is suitable for the anterior teeth area, and 1.6mm and above is suitable for the posterior molar area
Quality Inspection Agency: Focus on the phthalate limit requirements in Appendix C, and refer to GB/T22048 for the testing method

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 19342-2024 in English
Manual toothbrushes—General requirements and test methods
2024-10-26 -

GB/T 36391-2018 in English
Antibacterial toothbrush
2018-06-07