Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
crude oil residual oil plasma optical emission spectrometry distillate oil plasma optical emission spectroscopy heavy mechanical general techniques organic heat transfer material boiler main title bar products
GB/T 37160-2019 in English

GB/T 37160-2019 in English

VALID

Standard test method for determination of trace metals in heavy distillate,residual oil and crude oil-Inductively coupled plasma optical emission spectrometry(ICP-OES)

  • Issued on:2019-03-25
  • Implemented on:2019-10-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $120.00
$117.00
Standard No: GB/T 37160-2019
Document status: VALID
Title in English: Standard test method for determination of trace metals in heavy distillate,residual oil and crude oil-Inductively coupled plasma optical emission spectrometry(ICP-OES)
Title in Chinese: 重质馏分油、渣油及原油中痕量金属元素的测定 电感耦合等离子体发射光谱法
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2019-03-25
Implemented on: 2019-10-01
ICS Classification: 75.140-Waxes, bituminous materials and other petroleum products
Chinese Classification: E49-Other petroleum products
Professional Classification: GB-National Standard
Related Keywords: crude oil
residual oil
plasma optical emission spectrometry
distillate oil
plasma optical emission spectroscopy
Related Topics: metal element
Inductively Coupled Plasma
Determination of Sodium, Potassium and Vanadium in Coal Tar and Anthracene Oil by Inductively Coupled Plasma-Atomic Emission Spectrometry
Determination of Metal Elements in Solid Waste by Inductively Coupled Plasma Mass Spectrometry
trace metals
Relative Atomic Mass of Heavy Metals
trace metal metal element
Determination of Metal Elements in Solid Waste by Inductively Coupled Plasma Mass Spectrometry
Determination of Seven Trace Elements in Water by Inductively Coupled Plasma-Atomic Emission Spectrometry
Inductively Coupled Mass Spectrometry Lithium
Zinc content
plasma emission spectrometry
electronic heavy metal
electronic heavy metal
trace metal elements
Mass Spectrometry Metal Elements
dollar atomic mass
atomic mass weight
trace metal elements
trace metal elements
Relative Atomic Masses of Heavy Metals
GB/T 37160-2019
GB/T 37160
Element and Atomic Weight
inductively coupled plasma optical emission spectrometry
GBT37160
GB/T 37160-2019
Mass spectrometry metal ions
Inventor of mass spectrometry soft ionization
Medium I crude oil
Voltage versus energy spectrum of heavy elements
Corresponding wavelength of metal ion inductive coupling
Element emission spectral line overlapping separation correction method
Optocoupler component quality grade
Protoplast isolation methods and their advantages and disadvantages
Methods to separate overlapping spectra
gb t 37160

《GB/T 37160-2019重质馏分油、渣油及原油中痕量金属元素的测定 电感耦合等离子体发射光谱法》由TC280(全国石油产品和润滑剂标准化技术委员会)归口,TC280SC1(全国石油产品和润滑剂标准化技术委员会石油燃料和润滑剂分会)执行,主管部门为国家标准化管理委员会。


Introduction

In-depth interpretation of GB/T 37160—2019 National Standard of the People's Republic of China

This standard specifies the determination of aluminum, calcium, iron, potassium, magnesium, manganese, molybdenum, sodium, nickel, lead, vanadium and zinc in heavy distillates, residual oil and crude oil by inductively coupled plasma optical emission spectroscopy (ICP-OES). It is suitable for the determination of trace metals in heavy distillates, residual oil and crude oil, and provides important parameters for the later processing and production of oil products.

Comparison of standard frameworks

Chapter title Overview of main contents Keyword extraction
1 Scope Specifies the applicable scope and determination elements of ICP-OES. Heavy distillate oil, residual oil, crude oil, metal elements.
4 Instruments and Equipment Detailed list of required instrument specifications and requirements, including ICP-OES, balance, quartz cup, etc. Inductively coupled plasma optical emission spectrometer (ICP-OES), balance, quartz cup.
8 Preparation Describes reagent preparation, sample handling and environmental safety requirements. Reagent preparation, sample handling, fume hood, goggles.
9 Experimental Procedures Detailed description of the ICP-OES operating procedures and the method of establishing the standard curve. Instrument operation, standard curve, sample determination.

Explanation of professional terms and practical application cases

Inductively coupled plasma optical emission spectrometry (ICP-OES): a technology that uses high-temperature plasma to excite elements in a sample to emit a spectrum of a specific wavelength. Suitable for quantitative analysis of trace metal elements.

Internal standard element: a standard solution added during the analysis process to correct instrument drift and sample matrix effects to ensure the accuracy of the measurement results.

Analysis of standard formulation background and technological evolution

With the growth of global demand for petroleum resources and the improvement of environmental protection requirements, accurate determination of the content of metal elements in oil products has become a key link in production and processing technology optimization and product quality control. Traditional methods have limitations in detection sensitivity and simultaneous determination of multiple elements. ICP-OES has become the preferred technology due to its advantages of high sensitivity and simultaneous detection of multiple elements.

Sample only — not a preview of GB/T 37160-2019
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend