GB/T 38261-2019 in English
VALIDNanotechnology -- Determination of silver contents in biological samples -- Inductively coupled plasma mass spectrometry
- Issued on:2019-12-10
- Implemented on:2020-07-01
- File Format:PDF
- Delivery:Within 1 day
$233.00
《GB/T 38261-2019纳米技术 生物样品中银含量测量 电感耦合等离子体质谱法》由TC279(全国纳米技术标准化技术委员会)归口,主管部门为中国科学院。
Introduction
1. Background and purpose of the standard
With the widespread use of silver nanoparticles in daily necessities and medical devices, their potential risks to the human body have received increasing attention. This standard aims to provide a method for accurately measuring the silver content in biological samples, filling the gap in relevant national standards.
2. Core technology: Inductively coupled plasma mass spectrometry (ICP-MS)
ICP-MS is an efficient elemental analysis method suitable for the detection of trace and trace metals. This standard adopts the internal standard method, which effectively suppresses the matrix effect and monitors the instrument signal drift by adding internal standard elements (such as indium and rhodium) online.
3. Experimental process and key steps
| Steps | Operation content | Precautions |
|---|---|---|
| Sample pretreatment | Microwave digestion, acid removal, and volume determination | Pay attention to the complete digestion of the sample and the accuracy of the volume determination |
| Standard curve drawing | Prepare a series of silver standard solutions, and establish a standard curve with concentration as the horizontal axis and signal ratio as the vertical axis | The correlation coefficient should be ≥0.99 |
| Sample measurement | Add internal standard solution online to measure the signal intensity of the silver element in the sample | The blank value of the entire program must meet the requirements |
4. Data Analysis and Result Processing
Calculate the total mass and unit mass content of silver according to the formula: m = ρ_d × f × (m₁ / m₂ × 1000), X_i = m / m_T
5. Accuracy and Precision Analysis
The recovery rate of the blank spiked sample should be within the range of ±20% (relaxed to ±25% for low concentrations), and the precision calculation formula is: ε = [√(Σ(m_i - μ)^2 / (n-1))] / μ × 100%
6. Implementation Suggestions
Case Study: Detection of Biological Tissue Containing Silver-Coated Gold Nanorods
The silver content in rat kidney tissue was determined by standard method. The results showed that the silver concentration was 12.5 μg/L and the silver content per unit mass was 10.3 μg/g, which met the precision and accuracy requirements of the method.