GB/T 38577-2020 in English
VALIDDetermination of the biological activity for plant hormone-related secondary metabolites—Indicator plant method
- Issued on:2020-03-31
- Implemented on:2020-03-31
- File Format:PDF
- Delivery:Via email within 1~3 business days
$185.00
《GB/T 38577-2020植物激素类次生代谢产物的生物活性测定 指示植物法》由424-cnis(中国标准化研究院)归口,主管部门为国家市场监督管理总局。
Introduction
Technical Background of the Standard
This standard established for the first time an indicator plant method system based on wheat coleoptile, Amaranthus caudatus cotyledon and barley aleurone layer, solving the problems of poor repeatability and low standardization of traditional bioassay methods. The standard drafting team integrated multidisciplinary technologies such as plant physiology, analytical chemistry and metrology, and established the reproducibility of the method (RSD≤20%) through 5 years of verification.
Comparison of core assay principles
| Hormone type | Indicator plant | Detection index | Linear range (mg/mL) | Reference standard |
|---|---|---|---|---|
| Auxin | Wheat Triticum aestivum | Coleoptile elongation | 3.16×10-7-1×10-4 | NAA |
| Cytokinin | Amaranthus caudatus | GA3 |
Key Operation Points
Auxin Determination Case
Use class=instrument>Changmai 6135 variety of wheat, the following must be strictly controlled:
1. Light intensity <5 lux during dark culture
2. Length of coleoptile segments 6±0.2 mm
3. Pre-culture buffer replacement frequency 30 min/time
Buffer preparation specifications
Phosphate-citrate buffer (pH5.0) must be prepared and used immediately, where:
- The ratio of potassium dihydrogen phosphate (1.80 g/L) to citric acid (1.02 g/L) is strictly 1:0.567 (w/w)
- Sucrose concentration of 20 g/L can maintain osmotic pressure balance
Implementation suggestions
- Quality control: The recovery rate of the standard sample (85-115%) must be measured simultaneously for each batch of experiments
- Equipment calibration: The wavelength accuracy of the UV spectrophotometer needs to be calibrated with potassium dichromate solution every day
- Data verification: It is recommended to use Excel LINEST function for regression analysis, and it is effective only when R2≥0.98
Technology evolution analysis
Compared with the traditional mung bean hypocotyl bending method, this standard has the following advantages:
1. The detection sensitivity is increased by 102 times (the minimum detection limit of auxin is 3.16×10-7 mg/mL)
2. The detection cycle is shortened by 50% (the cytokinin determination only takes 72 hours)
3. For the first time, the comparable measurement of the activity values of the three hormones is achieved

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 17786-1999 in English
Frequency allocation of CATV
1999-07-01 -

GB/T 41519-2022 in English
Requirements for water resource protection during shale gas development
2022-04-15 -

GB 51055-2014 in English
Code for design of non-ferrous industrial plant structures
2014-12-02 -

GB/T 12827-2008 in English
Standard reference acetylene blank and standard practice for evaluation
2008-06-18 -

GB/T 286-1964 in English
Rolling bearings--Double-row radial spherical roller bearings--Types and basic dimensions
- -

GB 1886.87-2015/XG1-2022 in English
National Food Safety Standard — Food Additives — Beeswax,includes Amendment 1
2015-09-22 -

GB/T 13727-2016 in English
Specification for geological exploration of natural mineral water resources
2016-08-29 -

GB 4789.34-2016 in English
National Food Safety Standard—Food Microbiological Examination—Examination of Bifidobacterium
2016-12-23 -

GB/T 22911-2008 in English
Swamp eel
- -

GB 9395.1-1988 in English
Potassium silicate solution for use in electronic industry-Generality for analytical methods
-