《GB/T 39109-2020纺织品 二苯甲酮类紫外线吸收剂的测定》由TC209(全国纺织品标准化技术委员会)归口,TC209SC1(全国纺织品标准化技术委员会基础标准分会)执行,主管部门为中国纺织工业联合会。
Introduction
Analysis of the core content of the standard
This standard establishes a standardized method for the determination of 11 benzophenone ultraviolet absorbers in textiles using High Performance Liquid Chromatography-Diode Array Detector (HPLC-DAD). The detection range covers all kinds of textile products, the method determination limit is 10mg/kg, and the precision requirement is a relative standard deviation of ≤10%.
Comparison of key technical parameters
| Dimension | GB/T 39109-2020 | International similar standards | Conventional methods in the industry |
|---|---|---|---|
| Detector type | Diode array detector | Mass spectrometer detector | Ultraviolet detector |
| Pretreatment method | Methanol ultrasonic extraction | Accelerated solvent extraction | Soxhlet extraction |
| Chromatographic column type | Hydrophilic C8 column | C18 column | Silica gel column |
Key points for implementation of the method
Typical application case
When a sportswear company used this standard to detect the content of 2-hydroxy-4-methoxybenzophenone in sunscreen clothing, the following critical control points were found:
- The extraction temperature needs to be strictly controlled at 60±1℃
- The proportion of mobile phase B needs to be accurately adjusted to 80% at 42min in the gradient elution program
- The retention time of 2,3,4-trihydroxybenzophenone at a wavelength of 310nm should be 16.129min
Standard Evolution Analysis
Compared with the 2009 version, this standard has the following major technical breakthroughs:
- The number of test substances has been expanded from 6 to 11, with the addition of new ultraviolet absorbers such as 5-chloro-2-hydroxybenzophenone
- The multi-wavelength synchronous detection technology (258/280/310nm) is used to improve the method specificity
- The mobile phase formula (methanol-isopropanol-formic acid system) is optimized to improve the peak shape
Implementation suggestions
Special attention should be paid to laboratory operations:
- The standard stock solution should be stored at 4℃ in the dark and is valid for 3 months
- The sample should be cut into 5mm×5mm pieces to ensure the extraction efficiency
- It is recommended to add a blank control and a spike recovery experiment to each batch of tests

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 44722-2024 in English
Textiles―Determination of quinoline
2024-09-29 -

GB/T 16988-2013 in English
Quantitative Determination for Mixtures Of Special Animal Fibre and Wool
2013-12-17 -

GB/T 28189-2023 in English
Textiles―Determination of polycyclic aromatic hydrocarbons
2023-05-23 -

GB/T 18412.1-2006 in English
Textiles―Determination of the pesticide residues―Part 1: 77 pesticides
2006-05-25 -

GB/T 14575-2009 in English
Textiles - Tests for colour fastness - Comprehensive colour fastness
2009-06-19 -

GB/T 41559-2022 in English
Textiles—Determination of isothiazolone compounds
2022-07-11 -

GB/T 33269-2016 in English
Textiles--Polyester mixtures quantitative analysis--Nuclear magentic resonance spectroscopy method
2016-12-13 -

GB/T 9994-2018 in English
Conventional moisture regains of textile materials
2018-03-15 -

GB/T 42695-2023 in English
Textiles—Quantitative chemical analysis—Mixtures of kapok with certain other fibers
2023-05-23 -

GB/T 45519-2025 in English
Textiles—Fiber quantitative analysis—Intelligent identification method using microscope
2025-04-25