《GB/T 40248-2021人员密集场所消防安全管理》由TC113(全国消防标准化技术委员会)归口,TC113SC9(全国消防标准化技术委员会消防管理分会)执行,主管部门为应急管理部。
Introduction
Analysis of the core content of the standard
In view of the particularity of crowded places, this standard has constructed a complete management system consisting of 7 major chapters and 2 appendices, with a focus on strengthening the following aspects:
- Three-level responsibility system: clarify the joint liability of property owners, users, and unified management units
- Dynamic supervision mechanism: require daily fire inspections + monthly comprehensive inspections
- Technical prevention and control measures: propose quantitative indicators for the maintenance of fire protection facilities
Fire safety responsibility comparison matrix
| Responsible entity | Core responsibilities | Training requirements |
|---|---|---|
| Person responsible for fire safety | Approve the annual plan and ensure funding | Must undergo professional training |
| Fire safety manager | Organize and implement daily management work | It is recommended to have the qualification of a registered fire engineer |
| Fire control room attendant | Two people on duty with certificates for 24 hours | Must obtain a fire facility operator certificate |
Special requirements for typical places
Shopping malls and markets
It is explicitly prohibited to set up a connected ceiling. When it is necessary to set up a ceiling, it must meet the following technical requirements: open area ≥ 25%, height exceeding the eaves by 1 meter, and combustible materials are prohibited, etc.
Public entertainment venues
Mandatory regulations: ≥1㎡ external windows must be set every 20 meters, emergency broadcast switching devices must be installed in private rooms, and lamps must be kept at a distance of more than 0.5 meters from flammable materials.
Key points for the implementation of the standard
- Establish an electronic fire archive management system, including 12 types of information such as facility inspection reports
- The proportion of volunteer fire brigades shall not be less than 30% of the employed personnel
- The safety exit access control system must realize the automatic release function in case of fire
Technology evolution analysis
Compared with the old version of the specification, this standard adds:
1. Introducing the construction requirements of micro fire stations
2. Clarifying the configuration principles of the electrical fire monitoring system
3. Specifying the networking standards for the fire remote monitoring system

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 12474-2008 in English
Method of test for explosion limits of combustible gases in air
2008-06-26 -

GB/T 25208-2010 in English
Environmental test methods for fixed extinguishing systems
2010-09-26 -

GB 46034-2025 in English
Fire safety inspection rules for public assembly occupancies prior to opening of businesses
2025-08-01 -

GB 13495.3-2026 in English
Fire safety signs—Part 3: Requirements for the installation
2026-01-28