GB/T 40887.2-2022 in English
VALIDWheelchair containment and occupant retention systems for accessible transport vehicles designed for use by both sitting and standing passengers—Part 2: Systems for forward-facing wheelchair seated passengers
- Issued on:2022-10-12
- Implemented on:2023-02-01
- File Format:PDF
- Delivery:Via email within 5 business days
$437.00
| Standard No: | GB/T 40887.2-2022 |
| Document status: | VALID |
| Title in English: | Wheelchair containment and occupant retention systems for accessible transport vehicles designed for use by both sitting and standing passengers—Part 2: Systems for forward-facing wheelchair seated passengers |
| Title in Chinese: | 无障碍客车的轮椅车及乘坐者限位系统 第2部分: 前向式轮椅车乘坐者系统 |
| Language: | English |
| File Format: | Electronic (PDF) |
| Delivery: | Via email within 5 business days |
| Issued on: | 2022-10-12 |
| Implemented on: | 2023-02-01 |
| Chinese Classification: | C30-Medical apparatus and devices in general |
| Professional Classification: | GB-National Standard |
| Related Keywords: | occupant retention systems
passengers part accessible transport vehicles passengers introduction wheelchair containment |
| Related Topics: | wheelchair
Seated Forward Bend Test GB/T 40887.2 GB/T 40887.2-2022 Unmanned wheel wheelchair Quality requirements for wheelchair seat cushions |
《GB/T 40887.2-2022无障碍客车的轮椅车及乘坐者限位系统 第2部分: 前向式轮椅车乘坐者系统》由TC148(全国残疾人康复和专用设备标准化技术委员会)归口,主管部门为民政部。
Introduction
1. Core design specifications and technological breakthroughs
1.1 System space specifications
| Functional area | Minimum size | Material requirements |
|---|---|---|
| Wheelchair positioning area | 750×1300mm | Friction coefficient 0.65-0.80 |
| Grip height | 720-910mm | Diameter 25-40mm |
1.2 Dynamic performance threshold
Based on the verification indicators of Appendix B:
- Maximum acceleration load: 3g@rearward for 1.5 seconds
- Structural rigidity: deformation <50mm or fracture potential energy absorption>9.6kJ
II. Key test methodology
2.1 Collision dynamics simulation
| Test type | Acceleration module | Indicator verification |
|---|---|---|
| Braking (1g) | Figure A.1 Pulse spectrum | Point P offset ≤150mm |
| Turning (0.75g) | Figure A.3 Curve | Point H relative displacement ratio ≥1.1:1 |
2.2 Biomechanical verification
- Lumbar spine flexibility: flexion stiffness 175-225N·m/rad (Figure D.1)
- Knee displacement priority: Xknee/Xwheel ratio dynamic monitoring
III. Evolution of standard application
Comparison of the implementation gap between European and American standards:
| Parameter comparison | Requirements of this document | FMVSS® standard |
|---|---|---|
| Brake test load | 1g×272kg | 0.8g×300kg |
| Lock fatigue test | 5000 times | 3000 times |

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 19702-2021 in English
In vitro diagnostic medical devices -- Measurement of quantities in samples of biological origin -- Requirements for content and presentation of reference measurement procedures
2021-03-09 -

GB/Z 16886.22-2022 in English
Biological evaluation of medical devices—Part 22:Guidance on nanomaterials
2022-12-30 -

GB/T 22576.1-2018 in English
Medical laboratories—Requirements for quality and competence—Part 1:General requirements
2018-12-28 -

GB/T 40888-2021 in English
Aids for ostomy and incontinence—Irrigation sets—Requirements and test methods
2021-11-26 -

GB/T 41843-2022 in English
Assessment of rehabilitation set for classification of functioning,disability and health
2022-10-12 -

GB/T 26340-2010 in English
Adjustable rehabilitation training bed
2011-01-14 -

GB/T 21919-2022 in English
Laboratory medicine—Requirements for the competence of calibration laboratories using reference measurement procedures
2022-10-12 -

GB/Z 42217-2022 in English
Medical device —Validation of software for medical device quality system
2022-12-30