Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
similar heat pump area low temperature type heat pump water heater must key installation process water system ≥0℃ area ordinary type heat pump water heater determine heat consumption biological toxicity hygienic microclimate energy consumption rate limits
GB/T 41703-2022 in English

GB/T 41703-2022 in English

VALID

Design, installation and acceptance specifications for commercial & industrial and similar heat pump hot water system

  • Issued on:2022-10-12
  • Implemented on:2023-05-01
  • File Format:PDF
  • Delivery:Via email within 5 business days
Price(USD): $430.00
$418.00
Standard No: GB/T 41703-2022
Document status: VALID
Title in English: Design, installation and acceptance specifications for commercial & industrial and similar heat pump hot water system
Title in Chinese: 商业或工业用及类似用途的热泵热水系统设计、安装、验收规范
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 5 business days
Issued on: 2022-10-12
Implemented on: 2023-05-01
ICS Classification: 27.200-Refrigerating technology
Chinese Classification: J73-Refrigeration equipment
Professional Classification: GB-National Standard
Related Keywords: similar heat pump
area low temperature type heat pump water heater must
key installation process water system
≥0℃ area ordinary type heat pump water heater determine
heat consumption
Related Topics: hot water
hot water standard
Automatic booster pump
design installation
hot water system
System design and installation
GBT41703
GB/T 41703-2022
Heat pump water heaters for commercial and industrial and similar purposes
Design, installation and acceptance of heat pump hot water systems for commercial or industrial and similar purposes
Industrial equipment installation and hoisting acceptance
Industrial pump laboratory standards
Flowmeter installation acceptance
gb/t 41703-2022

《GB/T 41703-2022商业或工业用及类似用途的热泵热水系统设计、安装、验收规范》由TC238(全国冷冻空调设备标准化技术委员会)归口,主管部门为中国机械工业联合会。


Introduction

Analysis of the core content of the standard

This standard is applicable to electric vapor compression heat pump hot water systems with a heating capacity of ≥3000W, and focuses on regulating three major technical links:

Technical linksCore requirementsKey parameters
System design It is necessary to calculate the design hourly heat consumption, hourly heating supply and auxiliary heat source configuration Kh hourly variation coefficient, Qh heat consumption, Q heating supply
Equipment installation The load-bearing capacity of the host machine is ≥2 times the full load, the load-bearing capacity of the bracket is ≥4 times, and the pipeline needs 1.5 times the pressure test Hydraulic pressure test pressure, shock absorbing gasket thickness, insulation layer thickness
Project acceptance Acceptance of each item in accordance with NB/T 34067-2018 7 major project acceptance indicators

Key technical parameter calculation

Typical hotel project calculation case

Calculation of design hourly heat consumption of a 200-room hotel (160L/bed·day) at a cold water temperature of 5℃:

Qh =

Winter ventilation temperatureUnit typeAuxiliary heat source requirements
<0℃ area Low temperature type heat pump water heater Must be set
≥0℃ area Ordinary type heat pump water heater Determine after verification

Installation process specification

6.15 Key installation process

  1. Water system: The heating time of PPR pipe hot melting shall be controlled according to Appendix E (DN50 pipe requires 18±2 seconds)
  2. Electrical safety: The resistance of the conductor to the ground is >0.5MΩ, and different voltage lines are laid separately
  3. Lightning protection grounding: Outdoor metal parts shall be connected to the building lightning protection device with the same potential

Implementation recommendations

Winter operation guarantee measures

  • It is recommended to configure self-limiting temperature electric heating tape (maintaining power ≥30W/m) in low temperature areas
  • Air source units need to be equipped with inclined water collection trays (slope ≥5°)
  • Circulating pumps should be configured with one in use and one in standby

Standard evolution analysis

Main upgrades compared to the old version of the standard:

  • Added heat storage tank volume calculation formula (5.5.1)
  • Refine the flow rate requirements for different pipe diameters (Table 2 Closed system DN100 flow rate 1.3-1.8m/s)
  • Supplement the rain protection requirements for solenoid valve installation (6.15.11)