GB/T 4214.13-2021 in English
VALIDTest method for noise of household and similar electrical appliances—Particular requirements for range hoods and other cooking fume extractors
- Issued on:2021-08-20
- Implemented on:2022-03-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$214.00
| Standard No: | GB/T 4214.13-2021 |
| Document status: | VALID |
| Title in English: | Test method for noise of household and similar electrical appliances—Particular requirements for range hoods and other cooking fume extractors |
| Title in Chinese: | 家用和类似用途电器噪声测试方法 吸油烟机及其他烹饪烟气吸排装置的特殊要求 |
| Language: | English |
| File Format: | Electronic (PDF) |
| Delivery: | Via email within 1~3 business days |
| Issued on: | 2021-08-20 |
| Implemented on: | 2022-03-01 |
| ICS Classification: | 97.040.99-Other kitchen equipment |
| Chinese Classification: | Z32-Noise and vibration test methods |
| Professional Classification: | GB-National Standard |
| Related Topics: | suck
Uses and Test Methods GB/T 4214.13 GB/T 4214.13-2021 Test methods for noise from household and similar electrical appliances |
《GB/T 4214.13-2021家用和类似用途电器噪声测试方法 吸油烟机及其他烹饪烟气吸排装置的特殊要求》由TC46(全国家用电器标准化技术委员会)归口,TC46SC10(全国家用电器标准化技术委员会家用电器噪声分会)执行,主管部门为中国轻工业联合会。
Introduction
Analysis of the core content of the standard
This standard is equivalent to the international standard IEC60704213:2016, and specifies a professional testing method system for the noise characteristics of cooking fume treatment equipment such as range hoods.
Key technical requirements
| Test elements | Specific requirements | Special instructions |
|---|---|---|
| Test environment | Hard-wall test room/reverberation room/free-field environment | Selected according to GB/T3767-2016 and other standards |
| Operating conditions | Stable operation at the maximum speed for 10min | 4 hours of pre-operation aging is required |
| Load configuration | Standard muffler + piping system | See Figure 101/103 for size requirements |
Key points for test implementation
1. Appliance installation specifications
For island-type range hoods, the back is required to be 1cm±0.5cm away from the vertical wall and fixed by an elastic support device. Down-discharge systems must be embedded in the test cabinet according to the manufacturer's instructions.
2. Selection of measurement methods
The hexahedron measurement surface method specified in GB/T3767-2016 is preferred, with a standard measurement distance of 1m. When there is an obvious pure sound component, additional microphone points are required.
3. Data processing requirements
The measurement time of A-weighted sound pressure level is ≥30 seconds, and the standard deviation of sound power level is controlled: repeatability σr≤0.4dB, reproducibility σR≤1.0dB.
Analysis of Standard Evolution
This standard forms a supporting system with IEC61591:1997. The main technical changes include:
- Added test requirements for down-discharge systems
- Improved the noise separation measurement method for external fan devices
- Refined the filter pretreatment specifications for circulating devices
Implementation Suggestions
- It is recommended that enterprises establish standard test fixtures for muffler-duct systems
- For models with multiple air outlets, the upper air outlet connection test system is preferred
- Pay attention to background noise control, and the external fan noise should be regarded as background noise