GB/T 42750-2023 in English
VALIDMeasuring methods of optical radiation safety for wearable devices
- Issued on:2023-05-23
- Implemented on:2023-12-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$243.00
《GB/T 42750-2023可穿戴设备的光辐射安全测量方法》由TC284(全国光辐射安全和激光设备标准化技术委员会)归口,TC284SC4(全国光辐射安全和激光设备标准化技术委员会非相干光辐射安全分会)执行,主管部门为中国机械工业联合会。
Introduction
In-depth interpretation of the National Standard of the People's Republic of China GB/T 42750—2023
| Standard dimensions | Content comparison | Scope of application | Technical requirements |
|---|---|---|---|
| Measurement conditions | - Standard atmospheric conditions (temperature, humidity, pressure) - Darkroom environment requirements (illuminance, reflectance) - Power supply stability | Preparation for all wearable device tests | The deviation range is controlled within 0.2% to ensure data reliability |
| Measurement equipment | - Spectral radiation analyzer - Irradiance receiver - Radiance receiving device - Variable angle test bench - Standard light source | Professional laboratory environment | Equipment needs to be calibrated regularly to ensure measurement accuracy |
| Types of optical radiation hazards | - Ultraviolet, near-ultraviolet, and infrared hazards to the eyes - Blue light and thermal hazards to the retina - Ultraviolet, infrared and thermal hazards to the skin | Eye-worn devices and skin contact devices | Select measurement parameters according to different hazard types |
Analysis of standard formulation background and technological evolution
With the popularization of wearable devices, the issue of optical radiation safety has become increasingly prominent. GB/T 42750-2023 fills the gap in this field in China. It refers to international standards such as IEC and ISO and develops safety measurement methods applicable to different types of wearable devices in combination with China's actual situation.
Explanation of professional terms and practical application cases
- Eyewear equipment: refers to products that directly contact the eyes or emit light radiation at a very short distance, such as AR/VR glasses.
- Skin contact equipment: refers to products that directly contact the skin or emit light radiation at a very short distance, such as smart wearable health monitoring devices.
Implementation recommendations
To ensure that the optical radiation safety of wearable devices complies with national standards, the following measures are recommended:
- Strictly test under standard conditions to ensure stable environment and power supply.
- Select measuring equipment that meets the requirements and calibrate regularly to ensure accuracy.
- Select the corresponding measurement method and parameter settings according to different product types.
- Strengthen the safety awareness of operators and avoid looking directly at the light source.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 44605-2024 in English
Laser and laser-related equipment—Absorption distribution measurement of optical laser components—Photothermal mapping method
2024-09-29 -

GB/T 4799-2011 in English
The type designation for lasers
2011-12-30 -

GB/T 47524-2026 in English
Lasers and laser-related equipment—Test method for angle resolved scattering
2026-04-30 -

GB/T 18904.2-2002 in English
Simiconductor devices-Part 12-2:Optoelectronic devices-Blank detail specification for laser diodes modules with pigtail for fiber optic systems or sub-systems
2002-12-04 -

GB/T 13739-2011 in English
Test methods for laser beam widths,divergence angle and transverse mode
2011-12-30 -

GB/T 30117.2-2013 in English
Photobiological Safety of Lamps and Lamp Systems - Part 2: Guidance on Manufacturing Requirements Relating to Non-Laser Optical Radiation Safety
2013-12-17 -

GB/T 37396.1-2019 in English
Lasers and laser-related equipment—Standard optical components—Part 1:Components for the UV,visible and near-infrared spectral ranges
2019-05-10 -

GB/T 31358-2015 in English
General specification for semiconductor lasers
2015-02-04