GB/T 42826-2023 in English
VALIDRadio-controlled clocks―Signal receiving measurement method
- Issued on:2023-08-06
- Implemented on:2024-03-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$156.00
| Standard No: | GB/T 42826-2023 |
| Document status: | VALID |
| Title in English: | Radio-controlled clocks―Signal receiving measurement method |
| Title in Chinese: | 电波钟 信号接收测试方法 |
| Language: | English |
| File Format: | Electronic (PDF) |
| Delivery: | Via email within 1~3 business days |
| Issued on: | 2023-08-06 |
| Implemented on: | 2024-03-01 |
| ICS Classification: | 39.040.20-Clocks |
| Chinese Classification: | Y11-Horology |
| Professional Classification: | GB-National Standard |
| Related Keywords: | signal receiving measurement method
signal time code modulation signal standard time signal measurement method radio-controlled clocks |
| Related Topics: | Total Chlorine Determination Method in Minutes
radio signal Model reception radio signal test, no signal Temperature test for a few minutes Signal differential testing Basic methods of electromyographic signal detection: Signal cable testing Receive signal-to-noise ratio test method EMG signal collection method |
《GB/T 42826-2023电波钟 信号接收测试方法》由TC160(全国钟表标准化技术委员会)归口,主管部门为中国轻工业联合会。
GB/T 42826-2023 Radio-controlled clocks - Signal receiving measurement method
1 Scope
This document specifies the terms and definitions, and the signal receiving general measurement method for radio-controlled clocks.
It is applicable to the analogical or/and liquid crystal display or/and LED display radio-controlled clocks, and the radio-controlled clock movements can also refer to it.
2 Normative references
There are no normative references in this document.
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1
radio-controlled clock
quartz clock which can receive standard time signal (3.2) and automatically regulate time and calendar according to the received signal
3.2
standard time signal
time code modulation signal broadcasted from the national statutory time service institution by means of long wave
Note: For the specific information of time code signals in the world, see Annex A.
3.3
receiving state
state when the radio-controlled clock (3.1) receives the standard time signal (3.2)
4 Signal receiving measurement method
4.1 Test conditions
4.1.1 General environment
The test ambient temperature shall be 18 °C to 25 °C, the temperature fluctuation shall not be greater than 2 °C during the whole test and the relative humidity is 30 % to 70 %.
4.1.2 Power supply
The supply voltage for samples to be tested shall be the nominal operating voltage.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

GB/T 22772-2008 in English
Mechanical clocks with pendulum
2008-12-30 -

GB/T 6046-2016 in English
Analogue quartz clocks
2016-02-24 -

GB/T 33727-2017 in English
Analogue quartz clocks -- Fitting dimentions of movements to hands
2017-05-12 -

GB/T 20408-2016 in English
Radio-controlled analogue clocks
2016-02-24 -

GB/T 38021-2019 in English
Analogue quartz clocks—Timing accuracy
2019-08-30