Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
harmonic meters three-phase harmonic test device harmonic order harmonic mixture standard technical dimension fundamental power requirements harmonic power requirements accuracy stainless steel sink chinastandards.net aseptic packaging production lines bisulfite content
GB/T 44992-2024 in English

GB/T 44992-2024 in English

VALID

Testing equipment for harmonic meters of active energy

  • Issued on:2024-12-31
  • Implemented on:2025-07-01
  • File Format:PDF
  • Delivery:Within 1 day
Price(USD): $480.00
$466.00
Standard No: GB/T 44992-2024
Document status: VALID
Title in English: Testing equipment for harmonic meters of active energy
Title in Chinese: 谐波有功电能表检验装置
Language: English
File Format: Electronic (PDF)
Delivery: Within 1 day
Issued on: 2024-12-31
Implemented on: 2025-07-01
ICS Classification: 17.220.20-Measurement of electrical and magnetic quantities
Chinese Classification: N29-Electrical parametric test and power supply unit
Professional Classification: GB-National Standard
Related Keywords: harmonic meters
three-phase harmonic test device
harmonic order
harmonic mixture
standard technical dimension fundamental power requirements harmonic power requirements accuracy
Related Topics: electrical energy
organic functional molecules
Meter
Half-wave plate function
cable tuning device
Packaging Inspection Form

《GB/T 44992-2024谐波有功电能表检验装置》由TC104(全国电工仪器仪表标准化技术委员会)归口,TC104SC2(全国电工仪器仪表标准化技术委员会电工和电磁量测量设备分会)执行,主管部门为中国机械工业联合会。


Introduction

Analysis of the core content of the standard

Technical dimension Fundamental power requirements Harmonic power requirements
Accuracy level 0.02/0.05/0.1 level 0.2/0.5/1 level
Voltage range 30-300V (resolution 0.1V)
Harmonic order - 2-50th (amplitude error ±0.2%)

Key technical requirements

Mechanical properties

Protection level: not less than IP20, electrical clearance and creepage distance must meet the requirements of Table 1 (such as the minimum creepage distance of 6.3mm under 300V voltage)

Hanging meter system: Each meter position must be equipped with voltage/current output terminals, pulse interface and communication interface, and the current terminal must have open circuit protection function

Electrical performance

Harmonic source Output requirements:

  • Fundamental frequency stability: ±0.02% (49-51Hz range)
  • Harmonic phase control: 2-20th harmonic ±0.5°, 21-50th ±1°
  • Power stability: 0.02-level device ≤0.025%

Metering Performance Verification

Test Type Test Conditions Allowable Error
Fundamental Wave Energy Ic Current, cosφ=1.0 0.02 Level: ±0.02%
Single Harmonic h=50th, Ih=0.4I1 0.5 Level: ±0.605% (including H coefficient)
Combined Harmonics Appendix B Typical Waveform 0.2 Level: ±0.3%

Typical application scenarios

When a provincial metrology center uses a three-phase harmonic test device to verify smart meters:

  1. Test according to B.4 waveform (3rd/5th/7th harmonic mixture)
  2. Ambient temperature is controlled at 23±2℃
  3. 24-hour variation ≤0.06% (0.2-level device)

Implementation suggestions

Purchase acceptance: Focus on checking key items such as insulation resistance (≥10MΩ), basic error (Table 15-17), and monitoring system indication error (Table 25-26) in the factory inspection report

Periodic maintenance: Power frequency magnetic field immunity (0.5mT) and annual stability (0.02 level ≤±0.01%) need to be retested every year

Sample only — not a preview of GB/T 44992-2024
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend