Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
non-combustibility test method test method test procedure standard test procedure test method annex b slipform pavers anhydrous lanthanum chloride products detection yarn
GB/T 5464-2010 in English

GB/T 5464-2010 in English

VALID

Non-combustibility test method for building materials

  • Issued on:2010-09-26
  • Implemented on:2011-02-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $170.00
$165.00
Standard No: GB/T 5464-2010
Document status: VALID
Superseded by: GB/T 5464-2026 Non-combustibility test method of building materials
Superseded on: 2026-10-01
Title in English: Non-combustibility test method for building materials
Title in Chinese: 建筑材料不燃性试验方法
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2010-09-26
Implemented on: 2011-02-01
Superseding: GB/T 5464-1999 Non-combustibility test method of building materials
ICS Classification: 13.220.50-Fire-resistance of building materials and elements
Chinese Classification: C82-Fire protection technology
Professional Classification: GB-National Standard
Related Keywords: non-combustibility test method
test method
test procedure
standard test procedure
test method annex b
Related Topics: building materials
non-combustible building materials
gb/t5464
Building Material Standards
Non-combustibility test of building materials
GB/T 5464
non-flammable
GB/t+5464
gb5464
Non-combustibility test of building materials
GB/t+5464+
building material test
Building material test
Material non-combustibility test
Non-combustibility of building materials
Material flammability test method or
gb t 5464
Building material pressure testing machine
Material test
Experimental materials and methods
Flame Retardancy
building material test
Test method for noncombustibility of building materials
Test methods for building piping
non-combustible
Non-combustibility test
Flammability of building materials
Experimental materials and methods
building materials
GB/T5464 and
gb/t5464-2010
GB/5464
GB/T5464 or
national building materials
Flammability standard
Flame Retardant Building Materials
Material test
How to measure the non-conductivity of materials
GBT5464
GB/T 5464-1999
GB/T 5464-2010
Non-flammability test
Testing building materials for deflection
Building Materials Experimental Code

《GB/T 5464-2010建筑材料不燃性试验方法》由TC113(全国消防标准化技术委员会)归口,TC113SC7(全国消防标准化技术委员会防火材料分会)执行,主管部门为应急管理部。


1 Scope

This standard specifies a method of test for determining the non-combustibility performance, under specified conditions, of homogeneous building products and substantial components of non-homogeneous building products.
Information on the precision of the test method is given in Annex A.

2 Normative References

The following standards contain provisions which, through reference in this text, constitute provisions of this standard. For dated reference, subsequent amendments to (excluding correction to), or revisions of, any of these publications do not apply. However, all parties coming to an agreement according to this standard are encouraged to study whether the latest edition of these documents is applicable. For undated references, the latest edition of the normative document is applicable to this standard.
GB/T 16839.2-1997 "Thermocouples-Part 2: Tolerances" (idt IEC 60584-2:1982)
ISO 13943 "Fire Safety-Vocabulary"
EN 13238 "Reaction to Fire Tests for Budding Products-Conditioning Procedures and General Rules for Selection of Substrates"

3 Terms and Definitions

For the purpose of this standard, the terms and definitions given in ISO 13943, together with the following, apply:
3.1
Building product
Building material, element or component about which information is required, including installation, construction and composition.
3.2
Building material
A single basic substance or uniformly dispersed mixture of substances e.g. metal, stone, timber, concrete, mineral wool with uniformly dispersed binder, polymers.
3.3
Loose fill material
Material without any physical shape.
3.4
Homogeneous product
A product, consisting of a single material, having uniform density and composition throughout the product.
3.5
Non-homogeneous product
A product that does not satisfy the requirements of a homogeneous product. It is a product composed of more than one component, substantial and/or non-substantial.
3.6
Substantial component
A material that constitutes a significant part of a non-homogeneous product. A layer with a mass/unit area ≥1.0kg/m2 or a thickness ≥1.0mm is considered to be a substantial component.

4 Test Apparatus

4.1 General
4.1.1 The test apparatus shall be capable of creating the conditions specified in 7.1. A typical design of furnace is given in Annex B; other designs of furnace may be used.
4.1.2 All dimensions given in the description of the test apparatus are nominal values, unless tolerances are specified.
4.1.3 The apparatus shall consist of a furnace comprising essentially a refractory tube surrounded by a heating coil and enclosed in an insulated surround. A cone-shaped airflow stabilizer shall be attached to the base of the furnace and a draught shield to its top.
4.1.4 The furnace shall be mounted on a stand and shall be equipped with a specimen holder and a device for inserting the specimen-holder into the furnace tube.
4.1.5 Thermocouples, as specified in 4.4, shall be provided for measuring the furnace temperature and the furnace wall temperature. Annex C gives details of additional thermocouples to be used if the specimen surface temperature and the specimen centre temperature are required. The thermal sensor, as specified in 4.5, shall be provided for measuring the furnace temperature along its central axis.

Foreword I
1 Scope
2 Normative References
3 Terms and Definitions
4 Test Apparatus
4.1 General
4.2 Furnace, Stand and Draught Shield
4.3 Specimen Holder and Insertion Device
4.4 Thermocouples
4.5 Contact Thermocouple
4.6 Mirror
4.7 Balance
4.8 Voltage Stabilizer
4.9 Variable Transformer
4.10 Electrical Input Monitor
4.11 Power Controller
4.12 Temperature Indicator
4.13 Timing Device
4.14 Desiccator
5 Test Specimen
5.1 General
5.2 Preparation
5.3 Number
6 Conditioning
7 Test Procedure
7.1 Test Environment
7.2 Setting up Procedure
7.3 Calibration Procedure
7.4 Standard Test Procedure
7.5 Observations during Test
8 Expression of Results
8.1 Mass Loss
8.2 Flaming
8.3 Temperature Rise
9 Test Report
Annex A (Informative) Precision of Test Method
Annex B (Informative) Typical Designs of Test Apparatus
Annex C (Normative) Thermocouples for Additional Measurements
Annex D (Informative) Temperature Recording

Page: 1 / 0