Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
products shaped insulation products specimen size shaped insulation products refractory products determination % shaped insulation products device dense products tube-type furnaces customs clearance requirements fittings series scopethis
GB/T 5988-2022 in English

GB/T 5988-2022 in English

VALID

Refractory products—Determination of permanent change in dimensions on heating

  • Issued on:2022-03-09
  • Implemented on:2022-10-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $220.00
$214.00
Standard No: GB/T 5988-2022
Document status: VALID
Title in English: Refractory products—Determination of permanent change in dimensions on heating
Title in Chinese: 耐火材料 加热永久线变化试验方法
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2022-03-09
Implemented on: 2022-10-01
Superseding: GB/T 5988-2007 Refractory products—Determination of permanent change in dimension on heating
ICS Classification: 81.080-Refractories
Chinese Classification: Q40-Fireproof material in general
Professional Classification: GB-National Standard
Related Keywords: products shaped insulation products specimen size
shaped insulation products
refractory products determination
% shaped insulation products
device dense products
Related Topics: Immortalization
permanent material
GBT5988
GB/T 5988-1986
GB/T 5988-2007
GB/T 5988-2022
refractory material
permanent line change
Electromagnetic wire heat resistance test method
gbt5988-2022
gb/t5988-2007
New methods of chemical dosing
Material Durability International
gb/t 5988-2022
gb/t5988

《GB/T 5988-2022耐火材料 加热永久线变化试验方法》由TC193(全国耐火材料标准化技术委员会)归口,TC193SC3(全国耐火材料标准化技术委员会试验方法分会)执行,主管部门为国家标准化管理委员会。


Introduction

Background of Standard Revision and Technological Evolution

GB/T5988-2022, as the third revised version, integrates the contents of ISO2478:1987 and ISO2477:2005 international standards. The main technical changes include:

  • Delete the requirements for preparation of amorphous refractory samples
  • Add normative requirements for test furnaces and thermocouples
  • Optimize the sample height specification (60±2mm)
  • Add a new allowable error clause (Chapter 9)

Comparison of core test methods

Test items Dense shaped products Shaped insulation products
Specimen size 50mm×50mm×(60±2)mm or Φ50mm×(60±2)mm 100mm×114mm×65/75mm
Measurement accuracy 0.01mm (length measuring instrument) 0.1mm (comparator method)
Calculation formula Lc=(L1-L0)/L0×100% Added conversion formula for volume method

Key equipment requirements

Test furnace specifications

Must meet the following technical requirements:

  1. Temperature difference in sample loading area ≤±10℃
  2. Equipped with ≥3 thermocouples that comply with GB/T16839.1
  3. With temperature recording and display functions

Selection of measuring device

  • Dense products: Use a length measuring instrument with a dial indicator (accuracy 0.01mm)
  • Thermal insulation products: Use a vernier caliper or digital comparator (accuracy 0.1mm)

Implementation points and error control

Precautions for sample preparation

  • The 60mm direction of the dense product sample should be consistent with the molding pressurization direction
  • The measuring surface needs to be ground and kept parallel, and the parallelism deviation is ≤0.05mm
  • The measuring point of shaped insulation products should be 15mm away from the edge

Allowable error standard

Material type Error in the same laboratory Error between laboratories
Dense shaped products ≤0.10% ≤0.20%
Shaped insulation products ≤0.2% ≤0.4%

Typical application cases

High Alumina Brick Testing Example: A factory used the new standard to test LZ-75 high alumina bricks, and the linear change rate under the condition of 1500℃×3h was -0.25%, and the deviation of repeated test results was 0.08%, which met the standard allowable error requirements. The key control point is the consistency of the sample placement direction and the molding pressure direction.