Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
test method flash method determination method test report content test report carbon materials introduction gb/t hazardous waste storage facilities cold-setting urea-formaldehyde resins inorganic chemical products introduction gb/t
GB/T 8722-2019 in English

GB/T 8722-2019 in English

VALID

Test method for thermal conductivity of carbon materials

  • Issued on:2019-12-10
  • Implemented on:2020-07-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $150.00
$146.00
Standard No: GB/T 8722-2019
Document status: VALID
Title in English: Test method for thermal conductivity of carbon materials
Title in Chinese: 炭素材料导热系数测定方法
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2019-12-10
Implemented on: 2020-07-01
Superseding: GB/T 8722-2008 Method for the determination of thermal conductivity of graphite materials at median temperature
ICS Classification: 29.050-Conducting materials
Chinese Classification: Q51-Graphite material
Professional Classification: GB-National Standard
Related Keywords: test method
flash method determination method
test report content
test report
carbon materials introduction gb/t
Related Topics: Thermal Conductivity of Thermally Conductive Plastics
Thermal Conductivity
Test thermal conductivity iso
iso thermal conductivity
carbon material carbon material
Thermal conductivity of tellurium
Carbon Materials Laboratory
Hot wire method thermal conductivity meter
Hot wire method thermal conductivity meter
carbon peak material
carbon material peak
Thermal conductivity material
Material thermal conductivity
Carbon thermal conductivity
Thermal+
Super Thermally Conductive Material
Method for Determination of Thermal Conductivity
Use of thermal conductivity meter
Material pressure coefficient
Thermal conductivity of copper
GBT8722
GB/T 8722-1988
GB/T 8722-2008
GB/T 8722-2019
Determination of material elements
liquid thermal conductivity
Reference plate thermal conductivity calibration method
Calibration method of thermal conductivity of reference plate
How to calibrate thermal conductivity
How to calibrate thermal conductivity coefficient
Carbon material terminology PDF
Heat pipe test thermal conductivity
Conductive Carbon Moisture Test Method
Plastic thermal conductivity test method
Method for determination of element partition coefficient
Insulation material thermal conductivity tester
What is the method for measuring fixed carbon in carbon materials?
Retrieving method of carbon materials for aluminum
gb/t8722-2019
gb 8722 2019
gbt8722
gb/t 8722-2008

《GB/T 8722-2019炭素材料导热系数测定方法》由TC183(全国钢标准化技术委员会)归口,TC183SC15(全国钢标准化技术委员会炭素材料分会)执行,主管部门为中国钢铁工业协会。


Introduction

GB/T 8722-2019 Standard Overview

The National Standard of the People's Republic of China GB/T 8722-2019 "Determination Method of Thermal Conductivity of Carbon Materials" specifies the terms and definitions, principles, instruments and equipment, sample requirements, test procedures, result calculation and test report of thermal conductivity of carbon materials. This standard is applicable to the determination of thermal conductivity of block and flake carbon materials in different temperature ranges.

Analysis of Standard Formulation Background and Technology Evolution

GB/T 8722-2019 replaces GB/T 8722-2008 "Determination of Thermal Conductivity of Graphite Materials at Medium Temperature", and has made improvements mainly in the following aspects:

  • Added terms and definitions (Chapter 3)
  • Introduced the sampling direction regulations for the longitudinal heat flow method (4.4.1)
  • Modified the requirements for the number of longitudinal heat flow method tests (4.5.6)
  • Added the flash method determination method (Chapter 5)
  • Optimized the test report content (Chapter 6)

Comparative analysis of standard frameworks

Chapter GB/T 8722-2019 GB/T 8722-2008 New/modified content
Chapter 3 Added terms and definitions - New
Chapter 4 Applicable temperature range of longitudinal heat flow method extended to 100℃~800℃ Medium temperature range test Expanded
Chapter 5 New flash method determination method - New
Chapter 6 Optimized test report content Original report format Improved

Technical characteristics and applicable scope of the two measurement methods

1. Longitudinal heat flow method (Chapter 4)

  • Applicable temperature range:100℃~800℃
  • Principle characteristics:The sample is heated by direct current, and the thermal conductivity is calculated by one-dimensional longitudinal heat flow
  • Technical advantages:High measurement accuracy, suitable for bulk material testing

2. Flash method (Chapter 5)

  • Applicable temperature range:Room temperature to 2500℃
  • Principle characteristics:The thermal conductivity is calculated by the change in back surface temperature using high-intensity short-time pulse energy radiation
  • Technical advantages:Suitable for thin sheet material testing, especially suitable for high temperature range

Recommendations for the implementation of the standard

1. Equipment calibration and personnel training

Strictly purchase and calibrate instruments and equipment according to the standard requirements, including key measuring tools such as micrometers, vernier calipers, and thermocouples. It is recommended to provide professional training for experimental personnel to ensure that they are proficient in the operation of the two measurement methods.

2. Test environment control

  • The laboratory should maintain a constant temperature (recommended range: 20℃±2℃)
  • Avoid external interference factors (such as airflow, vibration, etc.) during the experiment
  • For the flash method, attention should be paid to the safety protection of the laser system

3. Data recording and processing

It is recommended to use professional data acquisition software for real-time recording and perform numerical rounding in accordance with the provisions of GB/T 8170. For the longitudinal heat flow method, special attention should be paid to the calculation accuracy of the lateral heat exchange coefficient ε.

4. Report Writing Specifications

  • Fill in the test report content strictly in accordance with the standard requirements
  • It is recommended to attach a temperature and thermal conductivity relationship curve
  • Abnormal data requires detailed explanation and analysis

Sample only — not a preview of GB/T 8722-2019
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend