GH/T 1319-2020 in English
VALIDMeasuring device of Infrared imaging temperature for cotton bale
- Issued on:2020-12-07
- Implemented on:2021-03-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
Price(USD):
$220.00
$214.00
$214.00
本标准规定了棉包红外成像温度测量装置的术语和定义、型号、技术要求、检验方法、检验规则、产品的标志、包装、运输和贮存。
本标准适用于棉包红外成像温度测量装置(以下简称测温装置)的制造、使用、检验等工作。
Introduction
Analysis of core technical requirements of the standard
| Technical indicators | Parameter requirements | Test methods |
|---|---|---|
| Infrared detector array | ≥320×240 | Factory report verification |
| Spatial resolution | ≤1.5mrad | Calculation using the formula α=a/f |
| Operating temperature range | -20℃~+50℃ | GB/T 2423.1/2 |
Comparative analysis of key technical indicators
The standard divides cotton bale infrared imaging temperature measurement device into cooling type (Z) and non-cooling type (F):
- NETD index: The cooling type can reach 50mK, which is better than the 100mK required by the standard
- Maintenance cost: The non-cooling type is maintenance-free and more suitable for warehousing scenarios
- Response speed: The cooling type takes 5-10 minutes to start, while the non-cooling type can be used immediately
Recommendations for the implementation of the standard
- Recommendations for warehouse installation spacing: Based on the maximum detection distance of 40m, one device is arranged for every 1600㎡
- Temperature calibration cycle: It is recommended to use a blackbody simulator for calibration every quarter
- Alarm threshold setting: It is recommended to set it to ambient temperature + 15℃ (refer to the spontaneous combustion point of cotton)
Background of technological evolution
This standard introduces infrared thermal imaging technology into the cotton storage field for the first time. Compared with traditional point temperature measurement:
| Comparison dimension | Infrared imaging technology | Traditional point temperature measurement |
|---|---|---|
| Detection efficiency | Whole warehouse scanning | Single point monitoring |
| Response speed | Millisecond level | Minute level |
| Positioning accuracy | ±0.5m | Unable to locate |