Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
machine accuracy introduction analysis increase moisture content control requirements implementation points geometric accuracy control accuracy requirements geometric accuracy axis end face runout ≤0.02mm working accuracy verification genetic quality control relevant instrument inspection programs pipeline pumps
JB 3105-1992 in English

JB 3105-1992 in English

VALID

Woodworking single head tenoning machine accuracy

  • Issued on:1992-07-01
  • Implemented on:1993-01-01
  • File Format:PDF
  • Delivery:RFQ
Price(USD): RFQ
Standard No: JB 3105-1992
Document status: VALID
Title in English: Woodworking single head tenoning machine accuracy
Title in Chinese: 木工单头直榫开榫机精度
Language: English
File Format: Electronic (PDF)
Delivery: RFQ
Issued on: 1992-07-01
Implemented on: 1993-01-01
Professional Classification: JB-Machinery
Related Keywords: machine accuracy introduction analysis
increase moisture content control requirements implementation points geometric accuracy control
accuracy requirements
geometric accuracy
axis end face runout ≤0.02mm working accuracy verification


Introduction

Analysis of the core content of the standard

This standard specifies two technical indicator systems, namely the geometric accuracy and working accuracy of the woodworking single-head straight tenon mortising machine, and is applicable to the quality control of special equipment for hardwood tenon processing.


Comparison of key technical indicators

Inspection items Measurement length Tolerance requirements (mm) Key changes (Compared with JB 3105-82)
Workbench flatness 630mm 0.15-0.25 Added diagonal direction detection
Tool axis radial runout - 0.02-0.03 Subdivided horizontal/vertical tool axis standards
Tenon thickness uniformity 100mm 0.10 Increase moisture content control requirements

Implementation points

Geometric accuracy control

Before inspection, the machine tool installation level must be adjusted with a spirit level. The longitudinal/lateral readings must not exceed 0.10/1000. Pay special attention to the G4 tool axis runout test:

  • Saw axis radial runout ≤0.03mm
  • Vertical tool axis end face runout ≤0.02mm

Working accuracy verification

The test piece should be made of hard miscellaneous wood with a moisture content of ≤15%. When processing double tenons, the following must be ensured:

  • Tenon width 8-20mm
  • Tenon length 100mm
  • Shoulder end face verticality ≤0.10/100

Technology evolution analysis

Compared with the 1982 version of the standard, the main improvements of the 92 version include:

  1. Add straightness detection in the diagonal direction of the worktable
  2. Refine the accuracy requirements of different tool axes (horizontal/vertical/center slot)
  3. Specify environmental control parameters such as moisture content of the specimen
  4. Introduce JB 4171 as the basic testing specification

Maintenance recommendations

Daily monitoring should focus on:

  • Check guide rail straightness (G2 item) every week
  • Check tool shaft radial runout every 500 hours
  • After replacing the tool, the P1 working accuracy must be recalibrated