JB/T 2379-2016 in English
VALIDMetal tubular electric heating elements
- Issued on:2016-01-15
- Implemented on:2016-06-01
- File Format:PDF
- Delivery:Via email within 2~4 business days
$446.00
| Standard No: | JB/T 2379-2016 |
| Document status: | VALID |
| Title in English: | Metal tubular electric heating elements |
| Title in Chinese: | 金属管状电热元件 |
| Language: | English |
| File Format: | Electronic (PDF) |
| Delivery: | Via email within 2~4 business days |
| Issued on: | 2016-01-15 |
| Implemented on: | 2016-06-01 |
| ICS Classification: | 25.180.10-Electric furnaces |
| Chinese Classification: | K61-Industrial electric heating equipment |
| Professional Classification: | JB-Machinery |
Introduction
Core Standard Evolution and Technology Upgrade
Compared with the 1993 version, the JB/T 2379-2016 standard has undergone 7 key technical upgrades: supplementing the medium applicability range, adding metal pipe material options, refining surface load indicators, and improving insulation material temperature classification. The latest version of the standard was jointly drafted by Zhenjiang Dongfang Electric Heating and other six units, reflecting the industry's technical consensus.
Analysis of product classification system
| Structural type | Code | Lead-out method | Typical application |
|---|---|---|---|
| Standard lead-out at both ends | A | Dual-end symmetric | General purpose gas/liquid heating |
| Single-end parallel lead-out | C | Parallel double rods | Compact space installation |
| Single-end coaxial lead-out | D | Concentric structure | Scenario with high sealing requirements |
The outer diameter tolerance of embedded components is strictly controlled within ±0.18mm (Φ6.5) to ±0.26mm (Φ22), which is 40% higher than the ordinary type, ensuring the interference fit effect with the metal heating body.
Comparison of key performance indicators
| Test items | Technical requirements | Test methods | Judgment criteria |
|---|---|---|---|
| Sealing test | 0.5MPa/5min | Hydrostatic pressure | No leakage |
| Insulation resistance | Cold state ≥50MΩ | Measured by megohmmeter | Calculated by formula (2) |
| Life test | 3000 hours | Rated operating conditions | Power attenuation ≤ 10% |
Material selection technical specifications
Magnesium oxide powder is classified according to the working temperature: low temperature type for below 400℃, medium temperature type for 400-600℃, and high temperature type for 600-850℃. When the surface temperature of the component exceeds 450℃, the brass lead rod is prohibited to prevent zinc volatilization.
Implementation suggestions and precautions
- Installation specifications: The bending radius should be ≥ 2 times the pipe diameter to avoid mechanical stress concentration
- Media compatibility: Stainless steel pipes must be made of 316L material in chloride ion environment
- Electrical safety: When the working voltage is >440V, it must comply with the additional requirements of GB 5959.1
- Maintenance cycle: It is recommended to test the insulation resistance value every 2000 hours
A petrochemical enterprise’s heating element did not control the surface load according to Table 2 (actual 9.5W/cm²>allowed 8W/cm²), resulting in a pipe melt-through accident. After the rectification, the Φ16mm components were selected in strict accordance with the standards to replace the original Φ12mm specifications, the load was reduced to 7.2W/cm², and the operating life was increased by 3 times.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

JB/T 4280-2004 in English
Medium frequency coreless induction furnace
2004-03-12 -

JB/T 14461-2023 in English
Technical requirements for industrial energy conservation assessment of steelmaking electric arc furnaces
2023-12-29 -

JB/T 8508-2025 in English
Electrical grade magnesium oxide
2025-05-09