JT/T 1071-2016 in English
VALIDTechnical requirements for variable frequency variable voltage power supply devices for port shore-based power supply
- Issued on:2016-10-21
- Implemented on:2017-01-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$223.00
| Standard No: | JT/T 1071-2016 |
| Document status: | VALID |
| Title in English: | Technical requirements for variable frequency variable voltage power supply devices for port shore-based power supply |
| Title in Chinese: | 港口岸基供电变频变压电源装置技术要求 |
| Language: | English |
| File Format: | Electronic (PDF) |
| Delivery: | Via email within 1~3 business days |
| Issued on: | 2016-10-21 |
| Implemented on: | 2017-01-01 |
| ICS Classification: | 03.220.40-Transport by water |
| Chinese Classification: | R45-Dedicated port facilities |
| Professional Classification: | JT-Transport |
| Related Keywords: | variable voltage power supply devices
standard technical requirements standard voltage power supply devices shore-based power supply technical requirements |
Introduction
Interpretation of the core content of the standard
Technical Requirements Standard for Variable Frequency and Voltage Power Supply Devices for Shore-based Power Supply of Ports (JT/T 1071-2016) is an important technical specification for the construction of shore power systems in ports in my country. It is applicable to power supply systems with a voltage of 0.4kV-11kV and a frequency of 50/60Hz. Its main technical framework includes:
| Technical module | Core requirements | Test standards |
|---|---|---|
| Power supply quality | Voltage fluctuation ≤±5%, frequency deviation ≤0.5Hz | GB/T 12325/15945 |
| Protection level | Power connection device ≥IP55, socket ≥IP65 | IEC 60529 |
| Safety protection | Overload 130% for 60s cut-off | GB/T 14048.1 |
| Environmental adaptability | -20℃~+60℃/100% humidity | GB/T 2423.2 |
Analysis of key technical requirements
1. Power quality control system
The standard requires the configuration of a dual closed-loop control system:
- Basic closed loop: power supply body regulation system (voltage/frequency accuracy ±1%)
- Advanced closed loop: shore-ship collaborative control system (supports three-phase imbalance adjustment)
2. Special environmental protection
Special provisions for port salt spray environment:
The case of Shanghai Yangshan Port shows that the service life of the power connection device with nickel-plated terminals is increased by more than 3 times in a salt spray environment.
Implementation Recommendations
Key Points for Equipment Selection
- The inverter capacity should be configured according to the ship load rate ≤40%
- Mobile power box should preferably use the standard container structure (GB/T 1413)
- Cable reels should be equipped with anti-condensation heaters
Operation and Maintenance Management Requirements
| Periodic | Inspection Items | Standard Values |
|---|---|---|
| Monthly | Grounding Resistance | ≤4Ω (GB 50169) |
| Quarterly | Insulation resistance | ≥10MΩ (GB/T 16927.1) |
| Annual | Temperature rise test | ≤70K (specified in Table 3) |
Standard Evolution Analysis
Main differences between this standard and the IEC/ISO/IEEE 80005-1 international standard:
- Stricter harmonic requirements: THD≤5% (international standard is 8%)
- New transient response indicator: Recovery time≤1.5s
- Strengthened salt spray protection: Metal parts are required to pass a 96-hour salt spray test