LS/T 1225-2022 in English
VALIDCode of practice for nitrogen controlled atmosphere technology in grain storage
- Issued on:2022-07-18
- Implemented on:2023-01-18
- File Format:PDF
- Delivery:Via email within 1~3 business days
Price(USD):
$220.00
$214.00
$214.00
Introduction
Analysis of the core content of the standard
| Technical elements | Requirements for flat warehouses | Requirements for shallow round warehouses |
|---|---|---|
| Airtightness standard | GB/T 25229 Level 2 and above | 500→250Pa half-life ≥300s |
| Nitrogen concentration | Insect prevention ≥95%, insecticide ≥98%, storage 90-95% | |
| Detection point layout | 9 points on 3 floors + 1 point inside the warehouse | 9 points on 2 floors + 1 point inside the warehouse |
Key technical points
Airtightness treatment plan
Appendix A of the standard specifies in detail the leakage treatment plan for different warehouse types:
- Wall treatment: Use water-based sealing paint or polyurethane epoxy resin material, and fill the cracks with acrylic paint mixed with putty
- Nitrogen production equipmentSupporting requirements: It should comply with JB/T 6427 standard, and the output purity should be ≥99.5%
- Process hole sealing: The vents are sealed with PVC film, and the cable holes are sealed with polyurethane material
Implementation and application suggestions
Typical application scenarios
Take rice storage in South China as an example:
- Start insect prevention mode (95% concentration) when the grain temperature reaches 20℃ in April and May
- Immediately switch to insecticide mode when insect pests are found (98% concentration maintained for 28 days)
- Combined with mechanical ventilation to disperse air in autumn and winter to prevent condensation
Safety management specifications
| Risk type | Prevention and control measures |
|---|---|
| Hypoxia risk | O₂≥19.5% before entering the warehouse, equipped with air respirators |
| Equipment safety | Regular inspection of pressure vessels and monthly leakage detection of pipelines |
| Operational specifications | Strictly implement the "three simultaneous" principle (inflation/detection/protection) |
Sample only — not a preview of LS/T 1225-2022

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

LS 1212-2008 in English
Guideline of pesticide management and application for stored grain
2008-04-22 -

LS/T 1237-2025 in English
Technical Regulations for Temperature Control Grain Storage Using Air Conditioners
2025-06-09 -

LS/T 1211-2008 in English
Technical criterion for grain and oils storage
2008-04-22