Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
fire hazard level fire hazard classification system hazard level ignition source type typical equipment protective fire hazard fire protection assessment transformer fire risk assessment position lamps transferable concrete mixing plant concrete mixing plant reactive blue kn-2g
NB/T 11307.1-2023 in English

NB/T 11307.1-2023 in English

VALID

Guide for assessing the fire hazard of electric equipment and materials Part 1:General guidelines

  • Issued on:2023-10-11
  • Implemented on:2024-04-11
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $180.00
$175.00
Standard No: NB/T 11307.1-2023
Document status: VALID
Title in English: Guide for assessing the fire hazard of electric equipment and materials Part 1:General guidelines
Title in Chinese: 电力设备与材料着火危险评定导则 第1部分:总则
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2023-10-11
Implemented on: 2024-04-11
ICS Classification: 29.035.99-Other insulating materials
Chinese Classification: K15-Electrical insulating material and its products
Professional Classification: NB-Energy
Related Keywords: fire hazard level
fire hazard classification system hazard level ignition source type typical equipment protective
fire hazard
fire protection assessment
transformer fire risk assessment
Related Topics: on fire
electric equipment
material fire
dangerous material
"electric equipment"
equipment and materials
Purpose of the guideline

本文件规定了电力设备与材料的着火危险、着火危险试验的基本原则、着火试验的分类以及适用的电力设备与材料。
本文件适用于电力设备与材料着火危险评定以及选择定量和定性着火试验的类型。


Introduction

Analysis of the core content of the standard

As a programmatic document for a series of guidelines, this standard establishes a four-dimensional framework for fire protection assessment of power equipment: hazard identification (Chapter 4), test principles (Chapter 5), test classification (Chapter 6) and equipment applicability (Chapter 7). Special emphasis is placed on special assessment requirements for key equipment such as oil-immersed transformers and dry-type reactors.


Fire hazard classification system

Hazard level Ignition source type Typical equipment Protective measures
Level I Arc/short-circuit current Transformer, switchgear Strengthen insulation monitoring
Level II Overheating/heat dissipation failure Reactor, capacitor Temperature early warning system
Level III Ignition from external fire source Cable, battery Application of flame retardant materials

Technology evolution background

This standard integrates the dual technical systems of GB/T 5169.1 and ISO 13943:2017, and establishes a special fire protection terminology library for power for the first time. Compared with the old version of XX/T standard, new assessment requirements for new equipment such as converter valve shunt reactor are added to reflect the development needs of new energy power grid.

Application case: Transformer fire risk assessment

When a 500kV substation used Article 4.7 of this standard to assess the oil-immersed transformer, it was found that there was an arc ignition risk at the bushing connection. By installing an infrared temperature measurement system and a pressure relief valve, the fire hazard level can be reduced from Level I to Level II.


Implementation recommendations

  1. Equipment selection stage: Give priority to certified products that have passed the full test in Chapter 6 of this standard
  2. Operation and maintenance monitoring focus: Establish a three-level warning index based on the hazard sources in Chapter 4
  3. Emergency treatment: Develop a differentiated fire extinguishing plan with reference to the test data in Chapter 5

Standard extension application

This document provides a top-level design of test methods for the subsequent 8 special standards (including cables, batteries, etc.). It is recommended to be used in conjunction with the GB/T 5169 series of standards to build a complete electrical fire protection assessment system.

Sample only — not a preview of NB/T 11307.1-2023
Page: 1 / 0
100%

Loading PDF document...

Error loading PDF. Please make sure the file is valid and try again.

We also recommend

  • NB/T 11389-2023 in English

    NB/T 11389-2023 in English

    Frequency domain dielectric spectrum test method for dielectric properties of insulating materials used in power transformers

    2023-05-30
  • NB/T 11307.4-2024 in English

    NB/T 11307.4-2024 in English

    Guidelines for the Evaluation of Fire Hazards in Power Equipment and Materials - Part 4: Commutation Valves and Parallel Reactors

    2024-09-24