本标准规定了蒸汽挂烫机的术语和定义、产品分类、要求、试验方法及检验规则、标志、包装、运输和贮存。
本标准适用于在家庭和类似场合使用,额定电压不超过250 V的蒸汽挂烫机。
Introduction
Analysis of the core technical requirements of the standard
| Key indicators | Normal pressure requirements | Pressure requirements | Test methods |
|---|---|---|---|
| Steam volume | ≥90% of nominal value | ≥90% of nominal value | 6.3.2 Weighing method |
| Energy efficiency | ≤0.87kW·h/kg | Not applicable | 6.4 Electricity measurement |
| Wrinkle removal rate | ≥90% | 6.8 Grid Method | |
| Bacteria Removal Rate | ≥99.99% | Appendix C Microbial Detection | |
Product Classification Technical Characteristics
Pole-type Steam Garment SteamerMust pass:
- Support rod load test: 7kg load for 2 hours without deformation (6.14.1)
- Assembly reliability: 300 times of disassembly and assembly test (6.14.3)
Handheld Garment SteamerSpecial requirements:
- Drop test: 76cm drop without leakage (6.17.2)
- Power cord length: ≥1.3m (5.13)
Details of key test methods
1. Wrinkle removal rate test (Clause 6.8)
A 200-grid (2cm×4cm) cotton load cloth is used and 800 standard folds are formed by fan-shaped folding. During the test:
- The steam nozzle is ironed vertically at a speed of 3-5cm/s
- Residual wrinkles>1cm are considered unqualified
- Calculation formula: λ=(N1-N2)/N1×100%
2. Life test (Clause 6.12)
Simulate a 500-hour use cycle (60min on/30min off), requirements:
- Test water hardness 30±10mg/L
- Clean scale every 50 cycles
- Steam must be discharged normally after the test
Standard implementation recommendations
Manufacturers
- Focus on the durability of the steam duct (must pass 120℃ high temperature + hot and cold cycle test)
- Pressure-type products must add a pressure seal test (Clause 6.18)
Testing agency
- The sterilization test needs to use standard strains of Staphylococcus aureus ATCC6538 and Escherichia coli 8099
- The steam volume test needs to control the ambient temperature to 25±2℃ (Clause 6.1)

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

QB 1872-1993 in English
leather for clothing
1993-11-13 -

QB/T 5408-2019 in English
Oral cleaning and care products Determination of erythritol content in toothpaste High performance liquid chromatography
2019-11-11 -

QB 1790-1993 in English
crystal rose
1993-04-29 -

QB 1156-1991 in English
lute
1991-06-04 -

QB/T 1980-1994 in English
demi-juice wine
1994-07-13 -

QB/T 1975-1994 in English
conditioner
1994-07-13 -

QB 1800-1993 in English
tree orchid oil
1993-04-29 -

QB/T 1758-1993 in English
R6 battery labeling, shrink sleeve machine
1993-04-15 -

QB 1659-1997 in English
toothbrush
1997-09-01