Sign In |Help & Support
ALL SECTORS
  • ALL SECTORS
  • GB(National Standard)
  • CB(Shipping)
  • CECS(Engineering Construction)
  • CJ(Urban Construction)
  • CY(News and Publication)
  • DB(Provincial Standard)
  • DL(Electricity & Power)
  • DZ(Geology & Mineralogy)
  • FZ(Spinning & Textile)
  • GA(Public Security)
  • HB(Aviation)
  • HG(Chemical Industry)
  • HJ(Environmental Protection)
  • JB(Machinery)
  • JC(Building Materials)
  • JG(Building & Construction)
  • JJ(Metering)
  • JT(Highway & Transportation)
  • LY(Forestry)
  • MT(Coal)
  • NB(Energy)
  • NY(Agriculture)
  • QB(Light Industry)
  • QC(Automobile & Vehicle)
  • QJ(Aerospace)
  • SH(Petrochemical)
  • SJ(Electronics)
  • SL(Water Resources)
  • SN(Commodity Inspection)
  • SY(Oil & Gas)
  • TB(Railway & Train)
  • YB(Ferrous Metallurgy)
  • YC(Tobacco)
  • YD(Telecommunication)
  • YY(Medical Device)
Database: 365,228(8 Aug 2026)
unpacking inspection → system maintenance → verification test → packaging life-saving grade maintenance key technical requirements maintenance items old version requirements key maintenance items dynamic load test implementation suggestions maintenance cycle management converter gas cleaning drainage channels shear performance testing
SC/T 8317-2025 in English

SC/T 8317-2025 in English

VALID

Fishing boat life-saving grade maintenance technical regulations

  • Issued on:2025-01-09
  • Implemented on:2025-05-01
  • File Format:PDF
  • Delivery:Via email within 1~3 business days
Price(USD): $165.00
$161.00
Standard No: SC/T 8317-2025
Document status: VALID
Title in English: Fishing boat life-saving grade maintenance technical regulations
Title in Chinese: 渔船救生筏检修技术规程
Language: English
File Format: Electronic (PDF)
Delivery: Via email within 1~3 business days
Issued on: 2025-01-09
Implemented on: 2025-05-01
ICS Classification: 65.150-Fishing and fish breeding
Chinese Classification: B94-Fishery machinery and tools
Professional Classification: SC-Aquaculture
Related Keywords: unpacking inspection → system maintenance → verification test → packaging
life-saving grade maintenance
key technical requirements maintenance items old version requirements
key maintenance items
dynamic load test implementation suggestions maintenance cycle management


Introduction

Interpretation of the core content of the standard

SC/T 8317-2025 establishes a standardized maintenance process including 8 key processes: from certificate verification → unpacking inspection → system maintenance → verification test → packaging and archiving, forming a closed-loop quality management system. The standard particularly emphasizes the two core indicators of throwable inflatable life raft: airtightness maintenance and integrity of emergency functions.

Comparison of key technical requirements

Maintenance items Old version requirements 2025 version new regulations
Float tire repair standard Damage area ≤100cm² ≤150cm² and length ≤80cm
Cylinder gas volume deviation Allow ±30g Negative deviation ≤20g
Safety valve test Visual inspection Neutral soap solution sealing test

Detailed explanation of key maintenance items

1. Maintenance of the charging system

The standard requires a six-step inspection of the quick release valve: including water corrosion inspection, safety device integrity verification, shaft core striker deformation inspection, etc. When inspecting the cylinder, an electronic scale with a graduation value of ≤5g should be used to weigh the gas to ensure that the CO₂/N₂ mixing ratio meets the original manufacturer's requirements.

2. Verification test system

Establish a four-level test system:

  • WP air tightness test: pressure drop of ≤5% in 1 hour
  • GI inflation test: inflation and molding are completed within 1 minute
  • NAP additional pressure test: 2 times the working pressure is maintained for 5 minutes
  • FS raft bottom strength test: 82.5kg dynamic load test


Implementation suggestions

Maintenance cycle management

It is recommended to establish a dual-track archive system: paper maintenance records (kept for 5 years) and electronic ledgers are maintained simultaneously. For life rafts with a 25-year service life, the full set of GI+NAP+FS tests must be performed in the 10th/15th/20th/25th year.

Common Problem Solving

When the canopy column safety valve is found to be leaking, the following should be checked first: ① The debonding condition of the valve body joint ② The rust condition of the spring ③ The aging degree of the rubber seal. The standard clearly stipulates that only 1 bubble is allowed to appear within 5 minutes during the sealing test.

Sample only — not a preview of SC/T 8317-2025