SN/T 4761-2017 in English
VALIDDetermination of fluorine in coal-High temperature hydrolyse-Auto potentiometric titration method
- Issued on:2017-05-12
- Implemented on:2017-12-01
- File Format:PDF
- Delivery:Via email within 1~3 business days
$97.00
Introduction
Standard Overview
This standard specifies the method for determining the fluorine content in coal using the high-temperature hydrolysis-automatic potentiometric titrator, and is applicable to the analysis of coal samples with a fluorine content ranging from 50μg/g to 1500μg/g.
Technical Principle
| Steps | Temperature Control | Key Reagents | Precision Requirements |
|---|---|---|---|
| High-Temperature Hydrolysis | 1100℃±50℃ | Ultrapure Water | ±2℃ |
| Fluoride Ion Conversion | 300-900℃ Gradient Temperature Rising | Silicon Fluoride Compounds | Conversion Rate ≥99.5% |
| Potentiometric Titration | Room Temperature | Lanthanum Nitrate Standard Solution | ±0.01mol/L |
Instrument configuration requirements
Core equipment:High-temperature tube furnace must meet the following requirements:
- Maximum operating temperature ≥1200℃
- Constant temperature zone length ≥80mm
- Equipped with quartz reaction tube (inner diameter 7-8mm)
Case data: A testing agency used a Thermo Scientific™ muffle furnace with a Metrohm 905 Titrando potentiometric titrator to measure the recovery rate of the standard substance GBW11126d, and the result was 98.7%-101.3%.
Method Innovation
Compared with the traditional distillation method, this standard:
- Shortened the analysis time from 4 hours to 40 minutes
- Adopted gradient temperature control technology to avoid fluoride volatilization loss
- Introduced automatic endpoint determination system to reduce human error
Implementation Suggestions
Key points of quality control:
- The particle size of coal samples should be controlled between 0.2-0.5mm
- The blank value and standard substance should be measured simultaneously for each batch
- The lanthanum standard solution should be stored at 4℃ in the dark and the shelf life should be ≤1 week
Abnormal handling: When the recovery rate exceeds the range of 90%-110%, the quartz tube sealing and carrier gas purity (≥99.99%) should be checked.

Loading PDF document...
Error loading PDF. Please make sure the file is valid and try again.
We also recommend
-

SN 0283-1994 in English
\"Method for Inspection of Dichlorodipyridinol Residues in Exported Poultry Meat\"
1994-02-18 -

SN/T 5486-2022 in English
Quarantine protocol for infection with seneca virus
2022-07-07 -

SN/T 2695-2010 in English
Protocol of detection for Aeromonas salmonicida
2010-11-01 -

SN/T 4877.1-2017 in English
DNA barcoding screening method—Part 1:Quarantine Clavibacter spp.
2017-07-21 -

SN/T 0244-1994 in English
\"General Rules for Inspection and Certification of Imported Mechanical and Electrical Instruments\"
1993-08-01 -

SN/T 3472-2012 in English
The quality conformity evaluation method of textiles for import and export-Clothing-Knitwear
2012-12-12 -

SN/T 3311-2012 in English
Detection method for influenza A 2009(H1N1)virus by real-time PCR at frontier port
2012-12-12